User Prog Trip
Trip generated by an onboard user program
96
This trip can be initiated from within an onboard user program using a function call which defines the sub-trip number
.
Recommended actions:
•
Check the user program
User Save
User Save error / not completed
36
The
User Save
trip indicates that an error has been detected in the user save parameters saved in non-volatile memory.
For example, following a user save command, If the power to the drive was removed when the user parameters were being
saved.
Recommended actions:
•
Perform a user save in Pr
mm.000
to ensure that the trip doesn’t occur the next time the drive is powered up.
•
Ensure that the drive has enough time to complete the save before removing the power to the drive.
User Trip
User generated trip
40 -89
112 -159
These trips are not generated by the drive and are to be used by the user to trip the drive through an application program.
Recommended actions:
•
Check the user program
Volts Range
Supply voltage out of range detected in Regen mode
169
The
Volts Range
trip is initiated, if the Regen
Minimum Voltage
(03.026) is set to a non-zero value and the supply voltage is
outside the range defined by
Regen Maximum Voltage
(03.027) and
Regen Minimum Voltage
(03.026) for more than 100
ms.
Recommended actions:
•
Ensure the supply voltage is operating within the drive specification.
•
Ensure Pr
03.026
and Pr
03.027
are set correctly
•
Check the supply voltage waveform using an oscilloscope
•
Reduce the level of supply disturbance
•
Set
Maximum Voltage
(03.027) to zero to disable the trip.
Watchdog
Control word watchdog has timed out
30
The
Watchdog
trip indicates that the control word has been enabled and has timed out
Recommended actions:
Trip
Diagnosis