RXi2-BP Hardware Reference Manual
Section 9
GFK-3187B
November 2020
Specifications
37
9.2
Temperature
Ambient temperatures and humidity values for the RXi2-BP IPC are provided in the following table. For
more details on operating temperature and its dependency on application software, please refer to the
Thermal Design section.
Temperature
Storage
-40 to 85°C (-40 to 185 °F)
Operating (Standard SKUs)
0 up to 70°C (32 to 158 °F), at zero airflow
Operating (Extended SKUs)
-40 up to 70°C (-40 to 158 °F), at zero airflow
Humidity
Storage
5 to 95% rH, non-condensing, at 40°C (104 °F)
Operating
9.3
Shock and Vibration
Shock and vibration values for the RXi2-BP IPC are provided in the following tables for both mounting
variants.
DIN Rail
Impact, operating
IEC 60068-2-27: 1987 (test Ea)
- 15g of 11ms half-sine pulse
- 3 shocks each axis (=18)
Sinusoidal Vibration, operating:
IEC 60068-2-6: 2008 (test Fc)
5 to 13.2 Hz @ .079 inch displacement
13.2 -33.9 Hz @ 0.7g acceleration
33.9-57 Hz @ .012 inch displacement
57-500Hz @ 2G
1 Oct/min, 10 Cycles a 3 axes
Mounting Panel
Impact, operating
IEC 60068-2-27: 1987 (test Ea)
- 15g of 18ms half-sine pulse
- 3 shocks each axis (=18)
Sinusoidal Vibration, operating:
IEC 60068-2-6: 2008 (test Fc)
5 to 13.2 Hz @ .079 inch displacement
13.2 -33.9 Hz @ 0.7g acceleration
33.9-57 Hz @ .012 inch displacement
57-500Hz @ 2G
1 Oct/min, 10 Cycles a 3 axes