Figure 7‐2. FIELDVUE DVC6005 HW2 Base Unit Assembly (continued)
APPLY LUB, SEALANT
NOTES:
1 SEE FIGURE 7‐3 FOR GAUGE CONFIGURATIONS
2. APPLY LUBRICANT KEY 65 TO ALL O-RINGS UNLESS OTHERWISE SPECIFIED
49B3261-C SHT 2 & 3
SECTION E-E
PIPESTAND MOUNTING
WALL MOUNTING
OUTPUT A
OUTPUT A
SUPPLY
OUTPUT B
1
E
E
SUPPLY
OUTPUT B