Chapter 2 Product Specifications 5
EV3200 Door Control Inverter User Manual
Items
Subitems
Specifications
Protection functions
Over current protection, over voltage protection, low voltage protection, over heat protection, overload
protection, output phase failure protection, motor protection, motor tuning error alarm, parameter
setting error alarm, door width auto-learning error alarm, OD/CD error alarm, pulse generator (PG) error
alarm, current detection circuit fault alarm, EEPROM read/write error alarm, over-speed protection
Application
environment
Inside, free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam, water drop, and
so on
Altitude
Lower than 1000m. Max altitude: 3000m (deration curve should be observed at 1000m ~ 3000m:
derated 10% for every rise of 100m)
Working
temperature
-10°C ~ + 40°C, temperature change less than 0.5°C /minute
Must be derated above 40°C: The output current must be derated 2% for every rise of 1°C.
Max temperature: 50°C
Humidity
Less than 95%RH, no condensation
Vibration
3.5mm (2 ~ 9Hz), 10m/s
2
(9 ~ 200Hz), 15m/s
2
(200 ~ 500Hz)
Environment
Storage
temperature
-40°C ~ + 70°C
Protection IP21
Structure
Cooling
Forced air cooling (EV3200-2S0004A and EV3200-2S0004S)
Natural air cooling (EV3200-2S0002A and EV3200-2S0002S)