![background image](http://html.mh-extra.com/html/emerson/ev3200/ev3200_user-manual_103366021.webp)
Chapter 5 Parameter Table 17
EV3200 Door Control Inverter User Manual
Parameter
Name
Setting range
Min. unit Default
Mod.
F3.17
Fan control
0: fan does not start during inverter
operation
1: fan starts when heatsink temperature is
higher than 65°C during inverter operation
2: fan starts during inverter operation
1 0 ×
F3.18
Percentage or pulse number selection
0: F1.01, F1.06, F1.13, F2.01, F2.06 and
F2.14 are percentages.
1: F1.01, F1.06, F1.13, F2.01, F2.06 and
F2.14 are numbers
0 0 ×
5.5 Door Width Self-learning Parameters F4
Parameter
Name
Setting range
Min. unit Default Mod.
F4.00 PG
type
0: 24V incremental PG
1: UVW incremental PG (5V)
1 0
×
F4.01
Pulse number per revolution
0 ~ 4000
1
100
×
F4.02 PG
direction
0: same as direction preset by PG wiring
1: reverse to direction preset by PG wiring
1 0
×
F4.03
Magnetic pole initial angle
0.0 ~ 359.9°
0.1
0
×
F4.04
Speed during door width auto-learning
2 ~ 20.00Hz
0.01Hz
5.00
×
F4.05
Selection of door-width auto-learning
0: disabled
1: enabled
1 0
×
F4.06
Low digits of pulse count for door wicth
0 ~ 9999 (pulse number)
1
0
×
F4.07
High digits of pulse count for door width
0 ~ 9999 (×10000)
1
0
×
F4.08
Actual door width
0 ~ 9999mm
1mm
0mm
×
F4.09
PG cable broken detection time for
asynchronous motor
0 ~ 10s
0.1s
0s
×
F4.10
Ratio of gear
1 ~ 100
1.0
1.0
×
F4.11
Asynchronous single/dual motor selection
0: single motor control (asynchronous or
synchronous).
1: dual motors control (asynchronous)
0 0
×
F4.12
Reserved