Maintenance and Troubleshooting Manual
Section 3: Meter maintenance
3-9000-764 Rev F
December 2017
Transducer cable removal and installation
29
4.
Cut the tie wraps for the transducer cable you are replacing
Figure 3-17
Flow meter
transducer tie wraps
5.
Use a wrench and loosen the cable gland (where the transducer cable enters the Base
Electronics Enclosure) until the transducer cable freely slides inside the gland.
6.
Remove the two bolts holding the Base Enclosure cover to the Transmitter Electronics
Enclosure using a 6mm Allen wrench.
7.
Lift the Transmitter Electronics Enclosure from the Base Enclosure. It may be necessary
to remove the ground lug wire and loosen the conduit connections prior to removal.
A.
C.
D.
A. Base enclosure transducer cable glands
B.
B. Cable ties (two locations for large size meters)
C. 3810 Series Ultrasonic Meter transducer port
D. Transducer mount and transducer cable