28
Epsilon Eb Digital Servo Drive Installation Manual
Figure 12:
Epsilon Auxiliary Power Supply Wiring Diagram
Alternate Power Supply Wiring
An Alternate Power Supply (APS) allows the drive to retain
motor position information and serial communications when
the main AC power supply is disconnected. You must reset the
drive, either using the reset button or a reset input, after AC
power is re-applied if the backup supplies have been active.
Enabling APS power is done by sliding open the access panel on
the side of the drive. Then move the jumper into the APS
position using needle nose pliers.
Side View
Front View
24 VDC
Important:
Slide the side access panel
up into the open position. Remove the
jumper from the AC position (Default)
and reinstall it into the 24 V position
(A.P.S.). The instruction on the side of
the drive will show which position to put
the jumper.
J1
+
-
2 A
Fuse
Single point PE
ground
(recommended)