Safety Notes
AXP 1410 Installation and Use (6806800H70F)
183
System Damage Munich
Running the system longer than 30 seconds with less than three fans damages the system.
If you exchange a fan (three remaining operating fans) ensure that the exchange procedure is
finished within 30 seconds.
System
Damage
A torn filter is ineffective in trapping particulates and will interrupt air flow distribution.
Before returning a filter to service, visually inspect it for tears or rips that may have occurred
during cleaning. Do not reinstall a torn filter. You may order replacement fan filters by
contacting your Emerson sales representative.
System Damage and Personal Injury
Fans may continue to rotate after power is removed. When exchanging a fan, rotating blades
in the fan may be exposed.
To prevent injury keep fingers and tools away from rotating blades in the fan.
System
Alarm
Bouncing the FTM during insertion may cause an alarm condition in the system.
Insert the FTM with a single, steady motion and do not force the module into the slot.
Pin
Damage
Forcing the FTM into the system may damage connector pins.
To avoid crushing or bending the connector pins, back the module out and insert it again if it
hangs during insertion.
System
Damage
Replacement of a PEM must be executed according to the recommended service interval of xx
minutes and be performed by a skilled service technician.
Personal
Injury
To avoid electric shock verify that the system is powered off and that all power sources are
disconnected before servicing any components internal to the system.
Summary of Contents for AXP 1410
Page 12: ...AXP 1410 Installation and Use 6806800H70F 12 List of Tables ...
Page 14: ...AXP 1410 Installation and Use 6806800H70F 14 List of Figures ...
Page 22: ...AXP 1410 Installation and Use 6806800H70F About this Manual 22 About this Manual ...
Page 25: ...System Overview AXP 1410 Installation and Use 6806800H70F 25 Figure 1 2 System Rear View ...
Page 62: ...System Installation AXP 1410 Installation and Use 6806800H70F 62 ...
Page 82: ...FRU Installation AXP 1410 Installation and Use 6806800H70F 82 ...
Page 118: ...Supported IPMI Commands AXP 1410 Installation and Use 6806800H70F 118 ...
Page 164: ...FRU Information and Sensor Data Records AXP 1410 Installation and Use 6806800H70F 164 ...
Page 201: ...Index AXP 1410 Installation and Use 6806800H70F 201 ...
Page 202: ...Index AXP 1410 Installation and Use 6806800H70F 202 ...
Page 203: ......