FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70F
)
126
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838
Critical and Non-Recoverable Thresholds
are Readable and Settable
Reading Type
Unsigned
Critical and Non-Recoverable
thresholds
0x2D, 0x35, 0x3F
(57, 67) Degrees C
Table 7-8 Sensor No. 31 FTM Temp 2
Feature
Raw Value/Description
Interpreted Value
Sensor Name
FTM Temp 2
Device
Sensor Type
0x01
Temperature
Class
0x01
Threshold
Sensor Owner LUN
0x00
Entity ID
0x0A
Entity Instance
0x60
Rearm mode
Auto
Hysteresis support
Readable/Settable
Threshold access support
Readable/Settable
Event message control
Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838
Critical and Non-Recoverable Thresholds
are Readable and Settable
Reading Type
Unsigned
Critical and Non-Recoverable
thresholds
0x2D, 0x35, 0x3F
(57, 67) Degrees C
Table 7-7 Sensor No. 30 FTM Temp 1 (continued)
Feature
Raw Value/Description
Interpreted Value
Summary of Contents for AXP 1410
Page 12: ...AXP 1410 Installation and Use 6806800H70F 12 List of Tables ...
Page 14: ...AXP 1410 Installation and Use 6806800H70F 14 List of Figures ...
Page 22: ...AXP 1410 Installation and Use 6806800H70F About this Manual 22 About this Manual ...
Page 25: ...System Overview AXP 1410 Installation and Use 6806800H70F 25 Figure 1 2 System Rear View ...
Page 62: ...System Installation AXP 1410 Installation and Use 6806800H70F 62 ...
Page 82: ...FRU Installation AXP 1410 Installation and Use 6806800H70F 82 ...
Page 118: ...Supported IPMI Commands AXP 1410 Installation and Use 6806800H70F 118 ...
Page 164: ...FRU Information and Sensor Data Records AXP 1410 Installation and Use 6806800H70F 164 ...
Page 201: ...Index AXP 1410 Installation and Use 6806800H70F 201 ...
Page 202: ...Index AXP 1410 Installation and Use 6806800H70F 202 ...
Page 203: ......