background image

Failure  to  follow  and  read  all  instructions  carefully   
before  installing  or  operating  this  control  could  cause 
personal injury and/or property damage

Installation Instructions for 

Heating & Air Conditioning 

1F78

5/2 Day Programmable Thermostat 

CONTENTS

Preparations .................................................. 1
Thermostat Details ........................................ 1
Removing Old Thermostat ............................. 1
Mounting and Wiring ...................................... 2
Check Thermostat Operation ......................... 3
Programming your Thermostat ...................... 4
Specifications ................................................ 6
Troubleshooting ............................................. 6

2

 THERMOSTAT DETAILS

HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

WIRE CUTTER/STRIPPER

1

 PREPARATIONS

To  prevent  electrical  shock  and/or  equipment  damage, 
disconnect electrical power to the system at the main fuse 
or circuit breaker until installation is complete.

CAUTION

!

Before  removing  wires  from  old  thermostat’s  switching  subbase, 
label  each  wire  with  the  terminal  designation  it  was  removed 
from.

1.

  Remove  Old Thermostat:    A  standard  heat/cool  thermostat 

consists of three basic parts:

 

a.  The cover, which may be either a snap-on or hinge type.

 

b.  The base, which is removed by loosening all captive screws.

 

c.  The switching subbase, which is removed by unscrewing  

 

  the mounting screws that hold it on the wall or adaptor plate.

2.

  Shut  off  electricity  at  the  main  fuse  box  until  installation  is 

complete. Ensure that electrical power is disconnected.

3.

  Remove the front cover of the old thermostat. With wires still 

attached, remove wall plate from the wall. If the old thermostat 
has a wall mounting plate, remove the thermostat and the wall 
mounting plate as an assembly.

4.

  Identify each wire attached to the old thermostat. 

5.

  Disconnect the wires from the old thermostat one at a time. DO 

NOT LET WIRES FALL BACK INTO THE WALL.

6.

  Install new thermostat using the following procedures.

PART NO. 37-6614C

Replaces 37-6614B

1027

Assemble tools required below.

3

 REMOVING OLD THERMOSTAT

Figure 1. Thermostat base

Mounting

hole

W903 Clip to

Disable EMR

Feature

W904 Clip for

Celsius Display

Mounting

hole

Electric/Gas

Switch

NOTE: Earlier models refer to 37-7006 for jumper locations.

W905 Clip for

Hydronic System

W

RH

B

RC

G

O

Y

+

-

+

-

GAS

ELEC

W904

W905

W903

www.white-rodgers.com

www.emersonclimate.com

YOUR THERMOSTAT REPLACES

Typical System Compatibility Chart

1E78

Standard Heat Only Two Wire Gas or Oil Fired Systems (24 volt)

Yes

Electronic Ignition Heat Only Two Wire Systems (24 volt)

Yes

Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt)

Yes

Standard Heat/Cool Systems (24 volt)

Yes

Heat/Cool Systems Electric Heat (24 volt)

Yes

Heat Only Electric Heat Systems (24 volt)

Yes

Cool Only Systems (24 volt)

Yes

Heat Pump Systems (No Aux. or Emergency Heat)

Yes

Hot Water Zone Heat Only (Two Wire) Systems

Yes

Hot Water Zone Heat Only (Three Wire) Systems

No

Line Voltage Heating or Baseboard 110/240 Volt Systems

No

Millivolt Systems Floor or Wall Furnaces

Yes

12 VDC Mobile Home Application

Yes

Multistage Systems

No

Systems Exceeding 30VAC, 1.5 Amp

No

Summary of Contents for 1F78

Page 1: ...mostat With wires still attached remove wall plate from the wall If the old thermostat has a wall mounting plate remove the thermostat and the wall mounting plate as an assembly 4 Identify each wire attached to the old thermostat 5 Disconnect the wires from the old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures PART NO 37 6...

Page 2: ...onic systems Both settings produce a very accurate temperature control and can be set to your personal preference As received the thermostat cycles the system just under 1 F With W905 clipped the system cycles at approxi mately 1 5 F Take care when securing and routing wires so they do not short to adjacent terminals or rear of thermostat Personal injury and or property damage may occur CAUTION TE...

Page 3: ...ER WIRE Reversing valve is energized when the system switch is in the HEAT position Fan Relay 5 CHECK THERMOSTAT OPERATION NOTE To prevent static discharge problems touch side of thermo stat to release static build up before touching any keys If at any time during testing your system does not operate properly contact a qualified service person Fan Operation If your system does not have a G termina...

Page 4: ...the next program period be gins Then the thermostat will automatically revert to the pro gram HOLD TEMPERATURE The thermostat can hold any tem perature within its range for an indefinite period without re verting to the programmed temperature Press HOLD button HOLD will be displayed Then choose the desired temper ature by pressing or The thermostat will hold the room temperature at the selected se...

Page 5: ...es you want during each period You may also want to look at the sample program table to get an idea of how the thermostat can be programmed 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH SAMPLE Heating Cooling Schedule Plan Factory Program 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 70 F 62 F 70 F 62 F 78 F 85 F 78 F 82 F 70 ...

Page 6: ... TO AUTOMATICALLY PROVIDE MAXIMUM COMFORT AND EFFICIENCY 7 SPECIFICATIONS ELECTRICAL DATA Electrical Rating MV to 30 VAC 50 60 Hz or D C 0 05 to 1 0 Amps Load per terminal 1 5 Amps Maximum Total Load All terminals combined THERMAL DATA Setpoint Temperature Range 45 F to 90 F 7 C to 32 C Operating Ambient Temperature Range 32 F to 105 F 0 C to 41 C Operating Humidity Range 0 to 90 RH non condensing...

Page 7: ...to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Furnace Cycles Too Fast or Too Slow narrow or wide temperature swing The location of the thermostat and or 1 the size of the Heating System may be influencing the cycle rate Digital thermostats normally provide precise temperature control and may cycle faster than some older mechanical models...

Page 8: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Page 9: ... com www emersonclimate com LÍNEA DE AYUDA PARA EL USUARIO 1 800 284 2925 White Rodgers es una división de Emerson Electric Co El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co ...

Page 10: ...ncionando correctamente Si el sistema funciona correctamente cambie el termostato Los ciclos de la caldera son 1 La ubicación del termostato y o el tamaño del Normalmente los termostatos digitales proporcionan un demasiado cortos o demasiado sistema de calefacción pueden influir en la control preciso de la temperatura y pueden apagarse y largos oscilación reducida o duración de los ciclos encender...

Page 11: ... AUTOMÁTICA EL MÁXIMO CONFORT Y EFICIENCIA 7 ESPECIFICACIONES DATOS ELÉCTRICOS Características eléctricas MV a 30 VCA 50 60 Hz o CC 05 a 1 0 amps carga por terminal Carga total máxima 1 5 amps todas las terminales combinadas DATOS TÉRMICOS Rango de temperaturas de referencia 45 F a 90 F 7 C a 32 C Temperatura ambiente operativa 32 F a 105 F 0ºC a 41ºC Humedad operativa 0 a 90 HR sin condensación T...

Page 12: ...igeración para el programa semanal Utilice la tabla que se encuentra al pie de la página para planificar las horas y temperaturas de programación que desea durante cada período También puede consultar la tabla de ejemplos de programas para tener una idea de cómo programar el termostato 1 2 3 4 1 2 3 4 EJEMPLO Plan de programación de calefacción refrigeración programa de fábrica 6 00 AM 8 00 AM 5 0...

Page 13: ...a MANTENER TEMPERATURA El termostato puede mantener cual quier temperatura dentro de su rango por un tiempo indefinido sin volver a la temperatura programada Presione el botón HOLD Apare cerá HOLD en la pantalla Luego elija la temperatura deseada pre sionando o El termostato mantendrá la temperatura am biente al valor seleccionado hasta que presione el botón RUN para volver a iniciar la ejecución ...

Page 14: ...ERIFIQUE EL FUNCIONAMIENTO DEL TERMOSTATO NOTA Para evitar problemas de descarga estática toque la parte lateral del termostato para liberar la estática acumulada antes de pulsar cualquier tecla Si en algún momento durante la prueba su sistema no funciona correcta mente póngase en contacto con un servicio técnico calificado Funcionamiento del ventilador Si su sistema no tiene una conexión terminal...

Page 15: ...exacto y pueden ajustarse según su preferencia personal Tal como se envía de fábrica el termostato apaga y enciende el sistema debajo de 1 F Con el cable de puente W905 cortado el sistema se apagará y encenderá a aproximadamente 1 5 F Al fijar y pasar los cables tenga cuidado de que no hagan cortocircuito con las terminales adyacentes o en la parte trasera del termostato Podrían producirse lesione...

Page 16: ...esión o articulada b La base que se quita aflojando todos los tornillos imperdibles c La subbase de conmutación que se quita desenroscando los tornillos de montaje que la sostienen sobre la pared o la placa adaptadora 2 Apague la electricidad en la caja de fusibles principal hasta que haya finalizado la instalación Asegúrese de que la alimentación eléctrica esté desconectada 3 Retire la cubierta d...