![Emerson Research X-STREAM Series Instruction Manual Addendum Download Page 26](http://html.mh-extra.com/html/emerson-research/x-stream-series/x-stream-series_instruction-manual-addendum_2400951026.webp)
Emerson Process Management GmbH & Co. OHG
1-6
X-STREAM XEFD
Instruction Manual
HASXEDE-IM-EX
07/2017
1.6 Nameplate Label
1.6 Nameplate Label (Examples)
Fig. 1-3:
Nameplate Label Details (exemplary)
Area
Description
Area
Description
The analyzer’s electrical data, manufac
-
turing data and serial number
Manufacturer address
Certification Data
IECEx /
EU (ATEX)
North America (CSA)
Area classification
II
other than mines
2
Category
2
Equipm. (Zone 1)
G
for explosive
G
as atmosphere
Class I
Flammable gases,
vapors or liquids
Zone 1
Zone 1 areas
Protection concepts
Ex
Explosion protected
db
flameproof
IIB+H
2
Group
II
, Gas Group
B
plus
Hydrogen
T4
Temperature Class (135 °C)
Gb
Equipment Protection Level
T
amb
Ambient Temperature Range
IP66
,
Type 4X
Enclosure Rating
(outdoor use)
AEx
Explosion protected (US)
Ex
Explosion protected (CAN)
d
flameproof
IIB+H
2
Group
II
, Gas Group
B
plus
Hydrogen
T3
Temperature Class (200 °C)
T
amb
Ambient Temperature Range
IP66
,
Type 4X
Enclosure Rating
(outdoor use)
Additional Division
Marking, if appli-
cable
--
Class I
Flammable gases,
vapors or liquids
Division 2
Division 2 areas
Groups BCD
all Gases, except
Acetylene
T3
Temperature Class (200 °C)
Certificate numbers
IECEx FTZU 08.0004X
FTZU 08 ATEX 0028 X
1714037X
Other
CE mark, number of Notified
Body for Quality assessment
Instruction note where to install
the explosion proof seal
Flammable/non flam
-
mable sample gas
Analyzer configured for use with
flammable or non flammable
sample gas
--
6
Additional warning: Do not open the instrument while energized. Consult manual!
CSA-C/US version
ATEX version
Emerson Process Management
GmbH & Co. OHG
Industriestrasse 1
D-63594 Hasselroth
!
100-240 V~ 50/60 Hz 3.0 - 1.5 A
MADE IN GERMANY
amb
-20 °C ≤ T ≤ +55 °C
IP 66 Type 4X
®
Explosionproof seal at
enclosure or within 2" of enclosure.
X-STREAM XEFD-##1##
SN: XED##2##
Date of Mfg: ##3##
AEx d IIB + H T3
2
Ex d IIB + H T3
2
Class I Zone 1
Class I, Division 2
Groups BCD T3
Joint anti-déflagrant à la
clôture ou à moins de 2" de la clôture
NE PAS OUVRIR SI UNE
ATMOSPHÈRE EXPLOSIVE GAZEUS
EST PREŚENTE
DO NOT OPEN WHEN AN
EXPLOSIVE GAS ATMOSPHERE
IS PRESENT
6