6
downward and the flow sensor in the top of the cell, so that the flow sensor only will give out
a signal when the water is full inside the cell housing.
4.
Ensure the water flow rate of the system is enough to fill completely the electrolytic cell. If
flow rate is low, the flow sensor will not detect water on the top of the cell housing and will
switch off the chlorine production. On the other hand, if flow rate is too high, we recommend
installing a by-pass with a valve to regulate the flow rate in the cell.
7.3 ELECTRICAL INSTALLATION
Proceed with the interconnections between the cell and the Control Unit according to the
following drawing (Fig 2).
1.
Connect the Control Unit to the general control box of the installation (A), so that the pump
and Emaux
SSC
one
®
unit are turned on and off simultaneously.
2.
Connect the filtration pump to the plug 230V (B).
3.
Connect the pH sensor into the connector (C). pH sensor includes 1.5-meter cable (10-
meter length cable upon request).
4.
Connect your automatic pool cover to the connect (D).
5.
Connect the electrolytic cell to the connector (E).
6.
Do not cut or modify the supplied cables.