10
9.1.2.
If the red LED light is lighting, this means that the flow sensor does not detect water flow in the
cell. Consequently, it will stop producing Chlorine immediately.
In this stage, the filtration pump will be programmed for working in cycles of 5 minutes every 20
minutes. This will ensure a minimum flow rate in the system and will avoid the pump to run in
dry conditions for a long period of time.
On the other hand, the pH dosing pump will continue working as normally.
9.1.3.
Emaux
SSC
one
®
unit has a self-cleaning cycle which reverses the cell polarity, reducing scale
build-up into the titanium plates and maximizing the cell life time.
GREEN LIGHT
BLUE LIGHT
NO LIGHT
CELL POLARITY
Polarity 1
Polarity 2
Cell is switched off and not
producing chlorine
When the cell reverses its polarity, the system will drop down the power to 0%, then will change
the polarity and slowly will raise to the previous settings.
By using the indicator WATER, the Hardness of the water can be selected and so, the period of
the cell polarity will be different:
SOFT: 12 hours.
MID: 8 hours.
HARD: 4 hours.
9.1.4.
Emaux
SSC
one
®
unit will detect if the pool cover is closed by lighting this indicator in green
color. When the pool cover is closed, the system will automatically turn down the cell power to
50% of your established setting power.
However, if the pool cover is closed and the WINTER MODE is ON,
the system will turn down the cell power 50% of the cell power turned
down by the pool cover.
For example, if during the operating period the cell power is working at 100%, by closing the
cover the power will drop down at 50%, and selecting WINTER MODE will drop at 75%.
9.1.5.
This indicator informs about the status of the filtration pump:
SOLID LIGHT
FLASHING LIGHT
NO LIGHT
PUMP
Filtration pump is
working in
normal
conditions.
Filtration pump is running but no flow is
detected in the electrolytic cell or the flow
rate is not enough to fill completely the
cell.
Filtration
pump is not