The control unit must be installed in places with sufficient ventilation. Fan openings should be kept 
free of any element that could obstruct them. The equipment should not be installed near flammable 
materials. 
The equipment should never be installed in places susceptible to flooding.  
It is important to reduce chlorine production to the minimum while the pool is covered. Otherwise, 
an excess of chlorine could degrade the pool materials. 
 

6.

 

WATER CHEMISTRY 

 
The  following  table  shows  the  recommended  levels  of  the  chemical  parameters  required  for  a 
proper quality of water in the pool by using Emaux 

SSC

 

one

®

Test your water periodically and ensure the levels are between the recommended range. 
 

Salt Level 

3500 – 5000 ppm 

Free Chlorine 

1.0 – 3.0 ppm 

pH 

7.2 – 7.6 

Cyanuric Acid (stabilizer) 

30 – 50 ppm 

Total Alkalinity 

80 – 120 ppm 

Calcium Hardness 

200 – 400 ppm 

Metals 

0 ppm 

 

6.1

 

SALT LEVEL 

 
The amount of salt required when using Emaux 

SSC

 

one

®

 is between 3500 and 5000 ppm, 

with 4000 ppm as a general recommendation. This means to add directly in the pool water 4 
Kg/m

3

Low concentration of salt (below 2500 ppm) will cause premature cell failure. 
High  concentration  of  salt  (above  6000  ppm)  may  cause  electro-oxidation  and  corrosion 
damage to the Stainless Steel pool fixtures. 
 
Salt required according to the volume of the pool: 

 

Pool volume (m

3

Salt (kg) 

 

Pool volume (Gallon) 

Salt (Pound) 

10 

40 

 

2,642 

88 

15 

60 

 

3,963 

132 

20 

80 

 

5,283 

176 

25 

100 

 

6,604 

220 

30 

120 

 

7,925 

264 

35 

140 

 

9,246 

308 

40 

160 

 

10,567 

352 

50 

200 

 

13,209 

440 

60 

240 

 

15,850 

528 

70 

280 

 

18,492 

616 

80 

320 

 

21,134 

704 

90 

360 

 

23,775 

792 

100 

400 

 

26,417 

880 

110 

440 

 

29,059 

968 

120 

480 

 

31,700 

1,056 

150 

600 

 

39,626 

1,320 

 

NOTE: Table based on 4000 ppm of salt per m

3

 of water.

 

 

Summary of Contents for SSC one

Page 1: ...1 SALT CHLORINATOR USER MANUAL one SSC ...

Page 2: ...he circuit conductors supplying the equipment To reduce the risk of electric shock connect the local common bonding grid in the area of the swimming pool or spa to these terminals with an insulated or bare copper conductor All field installed metal components such as rails ladders drains or other similar hardware within 3 meters of the pool or spa shall be bonded to the equipment grounding bus wit...

Page 3: ...a the above reactions will continuously recycle virtually eliminating the need to add sanitizing chemicals to your pool The only time you may need to add more salt to the pool is when water is replenished due to backwashing draining or splashing 4 2 THE CONTROL UNIT The control unit is provided with a microprocessor driven control system to regulate the percentage of chlorine production the operat...

Page 4: ...2 7 6 Cyanuric Acid stabilizer 30 50 ppm Total Alkalinity 80 120 ppm Calcium Hardness 200 400 ppm Metals 0 ppm 6 1 SALT LEVEL The amount of salt required when using Emaux SSC one is between 3500 and 5000 ppm with 4000 ppm as a general recommendation This means to add directly in the pool water 4 Kg m3 Low concentration of salt below 2500 ppm will cause premature cell failure High concentration of ...

Page 5: ...with the package in a minimum distance of 3 5 meters 11 5 ft from the swimming pool 1 5 meters 5 ft from the ground within 2 meters 6 5 ft from electrical enclosure and within 4 5 meters 15 ft from where the cell will be installed in a ventilated area and leaving enough free space of min 50 cm 20 in each side for servicing 2 DO NOT mount the Control Unit in a direct sun light 3 The Control Unit mu...

Page 6: ...ith a valve to regulate the flow rate in the cell 7 3 ELECTRICAL INSTALLATION Proceed with the interconnections between the cell and the Control Unit according to the following drawing Fig 2 1 Connect the Control Unit to the general control box of the installation A so that the pump and Emaux SSC one unit are turned on and off simultaneously 2 Connect the filtration pump to the plug 230V B 3 Conne...

Page 7: ... Fig 3 Before installation drill a hole in the top of the pipe with size approx 12 mm and make sure the sensor can pass through Install the saddle so that the hole in the pipe coincides with the sensor connection of the saddle b Saddle for the pH injector Fig 4 Before installation drill a hole in the pipe after the electrolytic cell with size approx 9 mm Install a socket with connection 3 8 female...

Page 8: ...swimming pools it is recommended keeping a level of 30 50 ppm of cyanuric acid stabilizer in the pool This will help to avoid the destruction of produced chlorine by the sun 4 Once the pool water is balanced there are three factors that the user can control which contribute to the amount of chlorine produced a Filtration time per day hours b The amount of salt in the pool c The Power output settin...

Page 9: ... Salt Renew with fresh water Low salt Add more salt into the pool water BLUE High heat sink temperature If the temperature of the heatsink reaches the internal thermal setting the system will automatically reduce the output power until the temperature remains constant No probe attached or probe fault pH dosing pump error or no acid pH readings has not changed after 5 dosing cycles Although only 1 ...

Page 10: ...raise to the previous settings By using the indicator WATER the Hardness of the water can be selected and so the period of the cell polarity will be different SOFT 12 hours MID 8 hours HARD 4 hours 9 1 4 Emaux SSC one unit will detect if the pool cover is closed by lighting this indicator in green color When the pool cover is closed the system will automatically turn down the cell power to 50 of y...

Page 11: ...e unit will operate according to the time scheduled The mode AUTO is switched off and the system will not produce chlorine even if the filtration pump is working If filtration pump is working in mode Auto it will be switched off after few seconds If the Salt Chlorinator has to operate according to an external timer the system must operate in mode AUTO and the timer scheduled for 24 hours so that o...

Page 12: ...edules proceed as follows a Setting the first working schedule Press the button SET a single green LED will appear indicating the starting hour of the first working schedule Press or to select the starting hour Press SET to confirm the starting time The range of operating hours will be lighting and the last hour will be flashing Press or to select the last hour of the working schedule Press SET to...

Page 13: ...f bathers heavy rain pool water renewal etc the chlorine concentration drops down considerably In this cases by using BOOST button the Emaux SSC one will generate chlorine at 100 of output power during 24 hours or until the same button is pressed again by the user How to proceed 1 Before Boosting chlorine it is recommended checking the chemical parameters paying special attention to the pH which s...

Page 14: ...from the holder and clean it with fresh water 2 Green LED light in POWER is slowly flashing 3 Press and hold the buttons and of pH Controller simultaneously The whole values of pH will turn green 4 Put the pH probe to the first buffer solution pH 4 Green lights will count down until the end 5 Clean the pH probe again with fresh water 6 Press and hold again the buttons and from the pH Controller Th...

Page 15: ... pump will NOT work in AUTO Mode in the following conditions 1 The current pH reaches the established Set Point 2 After 5 cycles the current pH does not change the value 3 The flow sensor in the cell does not detect flow rate 4 The filtration pump is not working 2 Mode MANUAL Push and hold the button SET from the pH Controller to switch on the dosing pump manually Once the button is released the d...

Page 16: ...EANING PROCEDURE If scale has been formed in the plates of the cell the first cleaning procedure is the following 1 Turn off power to the SSC one unit before removing the electrolytic cell 2 Once removed look inside the cell and inspect for scale formation light colored crusty or flaky deposits on the plates and for any debris which has passed through the filter and caught on the plates 3 Try to r...

Page 17: ...ool cover is installed and connected to the SSC one unit the system will detect it and the production will drop the half again So from the initial chlorine production now is reduced 75 Reduce the schedule time at minimum working period according to the aims of the pool in winter season Check periodically the complete installation the storage acid level and the electrolytic cell b Non working perio...

Page 18: ...rated 6 Slow flashing blue light pH dosing pump error or no acid solution Check dosing pump pipes foot valve and injection point If necessary clean the components with fresh water Check the volume of acid solution in the chemical storage tank Prepare an acid solution more concentrated Levels of Free Chlorine are very low Check the output power range Check the flow rate in the electrolytic cell Ver...

Page 19: ...d in similar equipment or installation type 4 Damage due to unauthorized product modifications or failure to use Emaux original replacement parts 5 Damage caused by negligence or failure to properly maintain products as specified in this manual 6 Damage caused by failure to maintain water chemistry in conformity with the standards of the swimming pool industry for any length of time 7 Damage cause...

Page 20: ...echnical operations Emaux is not liable for any loss of time inconvenience incidental expenses such as labor cost phone calls legal cost or material cost incurred in connection with the replacement or removal of the equipment or any other consequential or incidental damage on persons or assets Emaux will be not responsible for any business profit loss or operation stop due to the non conformity pr...

Reviews: