4
The control unit must be installed in places with sufficient ventilation. Fan openings should be kept
free of any element that could obstruct them. The equipment should not be installed near flammable
materials.
The equipment should never be installed in places susceptible to flooding.
It is important to reduce chlorine production to the minimum while the pool is covered. Otherwise,
an excess of chlorine could degrade the pool materials.
6.
WATER CHEMISTRY
The following table shows the recommended levels of the chemical parameters required for a
proper quality of water in the pool by using Emaux
SSC
one
®
.
Test your water periodically and ensure the levels are between the recommended range.
Salt Level
3500 – 5000 ppm
Free Chlorine
1.0 – 3.0 ppm
pH
7.2 – 7.6
Cyanuric Acid (stabilizer)
30 – 50 ppm
Total Alkalinity
80 – 120 ppm
Calcium Hardness
200 – 400 ppm
Metals
0 ppm
6.1
SALT LEVEL
The amount of salt required when using Emaux
SSC
one
®
is between 3500 and 5000 ppm,
with 4000 ppm as a general recommendation. This means to add directly in the pool water 4
Kg/m
3
.
Low concentration of salt (below 2500 ppm) will cause premature cell failure.
High concentration of salt (above 6000 ppm) may cause electro-oxidation and corrosion
damage to the Stainless Steel pool fixtures.
Salt required according to the volume of the pool:
Pool volume (m
3
)
Salt (kg)
Pool volume (Gallon)
Salt (Pound)
10
40
2,642
88
15
60
3,963
132
20
80
5,283
176
25
100
6,604
220
30
120
7,925
264
35
140
9,246
308
40
160
10,567
352
50
200
13,209
440
60
240
15,850
528
70
280
18,492
616
80
320
21,134
704
90
360
23,775
792
100
400
26,417
880
110
440
29,059
968
120
480
31,700
1,056
150
600
39,626
1,320
NOTE: Table based on 4000 ppm of salt per m
3
of water.