5
6.2
TYPE OF SALT
The most common salt used in swimming pools with Salt Electrolysis is Sodium Chlorine (NaCl)
that is 99% pure. DO NOT use the following types of salts:
rock salt;
salt with more than 1% yellow prussiate of soda;
Salt with more than 1% of anti-caking additives;
Iodized salt.
6.3 ADDING AND REMOVING SALT IN THE SWIMMING POOL WATER
Before adding the salt into the pool, turn the filtration pump on and the filtration valve manifold
in position “Filtration”.
Add the salt directly into the pool or balance tank and do not allow the salt to sit in a pile on
the bottom of the pool.
Keep the filtration system running for 24 hours using the Main Drain or vacuum suction nozzle
as a main suction line.
The only way to remove the salt in the pool water is to partially drain the pool and refill with
fresh water.
7
.
INSTALLATION
7.1 CONTROL UNIT (Fig. 1)
The Emaux
SSC
one
®
unit is contained in a rain tight enclosure that is suitable for outdoor
mounting (IPX4 waterproof). However, the following points must be taken into consideration for
a correct installation of the Emaux
SSC
one
®
unit:
1.
Install the Control Unit using the template paper sheet provided with the package in a
minimum distance of 3.5 meters (11.5 ft.) from the swimming pool, 1.5 meters (5 ft.) from
the ground, within 2 meters (6.5 ft.) from electrical enclosure, and within 4.5 meters (15 ft.)
from where the cell will be installed, in a ventilated area and leaving enough free space of
min. 50 cm (20”) in each side for servicing.
2.
DO NOT mount the Control Unit in a direct sun light.
3.
The Control Unit must be installed far away from the chemical storage, especially from acid
because it can corrode the electronics inside the unit.
4.
It must be kept away from heat sources and any equipment which produce heat.
5.
Plug-in power supply into a suitable weatherproof outlet socket with circuit breaker.
6.
Before fixing the Control Unit, make sure that the power cable and cell cable also reach the
Control Unit.
7.2 CELL (Fig. 2)
The following points must be noted for a proper installation of the cell:
1.
Install the cell always after all the other pool equipment (pump, filter, heating system…).
2.
It is very important to install the cell always higher than the top of the filter. The cell installed
in a lower level may keep water stored in the cell and cause a wrong message of the flow
switch. The presence of water in the cell does not mean getting a circulation flow rate.
3.
The cell must be always installed in horizontal position, with the connections placed face