15
The dosage is carried out in cycles of 5 minutes dosing followed by 20 minutes of stand-by.
These cycles avoid over-dosage of acid in the pool.
If after 20 minutes the current pH does not reach the Set Point, the dosing pump will switch on
again for 5 minutes more or until the pH reaches the set point.
If after 5 cycles the pH reading has not changed, a blue LED light in OPERATION STATUS will
be flashing informing there is a problem with the dosing pump or with the acid solution.
The dosing pump will NOT work in AUTO Mode in the following conditions:
1.
The current pH reaches the established Set Point.
2.
After 5 cycles the current pH does not change the value.
3.
The flow sensor in the cell does not detect flow rate.
4.
The filtration pump is not working.
2)
Mode MANUAL:
Push and hold the button SET from the pH Controller to switch on the dosing pump manually.
Once the button is released, the dosing pump will stop dosing.
This mode can help the system to reach the Set Point faster, but it is always recommended
allowing a certain period of time between dosages in order to let the acid mix with the pool
water.
No special conditions are required for running the dosing pump in Manual Mode.