![Elsner Vari KNX 3L-TH-D Installation And Adjustment Download Page 45](http://html.mh-extra.com/html/elsner/vari-knx-3l-th-d/vari-knx-3l-th-d_installation-and-adjustment_2396528045.webp)
44
Parameter setting
Sensor Vari KNX 3L-TH-D
• Status: 19.10.2016 • Errors excepted. Subject to technical changes.
Specify below which brightness the device should recognise "night" and with which
hysteresis this is to be outputted.
Set the delay for the switching and in which cases the switch output sends and which
value is output at night.
6.8.
Humidity Measurement
Select, whether a
malfunction object
is to be sent if the sensor is faulty.
Use
Offsets
to adjust the readings to be sent.
The unit can calculate a
mixed value
from its own reading and an external value. Set
the mixed value calculation if desired. If an external portion is used, all of the following
settings (threshold values, etc.) are related to the overall reading.
delays received via communication objects
• never
• after power supply restoration
• after power supply restoration and
programming
Night is recognised below Lux
1 ... 1000; 10
Hysteresis in Lux
0 ... 500; 5
Delays can be set via objects
(in seconds)
No • Yes
Switching delay on night
none • 1 s … 2 h
Switching delay on day
none • 1 s … 2 h
Switching output sends
• on change
• on change to night
• on change to day
• on change and periodically
• on change to night and periodically
• on change to day and periodically
Send cycle
(if sent periodically)
5 s ... 2 h
Object value at night
0 • 1
Use malfunction object
No • Yes
Offset in 0.1°C
-50…50; 0
Use external measured value
No • Yes
Ext. Reading proportion of the total reading
5% • 10% • ... • 50% • ... • 100%