106
Parameter setting
Weather Station Suntracer KNX sl
• Version: 14.07.2016 • Technical changes and errors excepted.
Set the delay times. If the delays are specified via communication object, then a start-
ing value and the possible setting range is defined.
Solar protection position and auto-guiding
Solar protection extends the shading automatically if
•
the sun is coming from the set direction and
•
the brightness of the set threshold value
•
is exceeded over a period longer the extension delay time.
For the movement position "Solar protection" auto-guiding can be set. Settings for
slats are only displayed if the shading for the façade has been defined as having slats
(see
Façade safety
, Seite 94).
Without auto-guiding a fixed position is travelled to.
Extension delay (in minutes)
(
when specified by parameter:
valid until first call)
1 ... 240
Minimum extension delay
that can be set (in minutes)
(for specification by parameter)
1 ... 240
Maximum extension delay
that can be set (in minutes)
(for specification by parameter)
1 ... 240; 40
Incrementally (in minutes)
(for specification by parameter)
1 ... 10
Brief delay (in seconds)
(
when specified by parameter:
valid until first call)
1 ... 3600; 10
Minimum short delay
(in seconds)
(for specification by parameter)
1 ... 3600
Maximum short delay
(in seconds)
(for specification by parameter)
1 ... 3600; 120
Increment (in seconds)
(for specification by parameter)
1 ... 240
Retraction delay (in minutes)
(
when specified by parameter:
valid until first call)
1 ... 240; 30
Minimum extension delay
that can be set (in minutes)
(for specification by parameter)
1 ... 240; 10
Maximum extension delay
that can be set (in minutes)
(for specification by parameter)
1 ... 240
Incrementally (in minutes)
(for specification by parameter)
1 ... 10