Date: 20.04.2016
GB
37/135
1.4 Mechanical specification
1.5 Actuation magnets
Note The switching distance can be reduced when all off-set
tolerances are used (see section 5 Mounting).
Housing material
VA 1.4571 (alternatively VA 1.4305,
1.4401)
Cable gland
NBR (M12x1.5)
Mounting
Sensor housing has M30x1.5 external
thread; for use in either a threaded hole or
with lock nuts
Ambient temperature range
Current rating I
i
: 0 ... 60 mA
-25 °C ... 70 °C (temperature class T6)
-25 °C ... 85 °C (temperature class T5)
-25 °C ... 85 °C (II 2D / II 1D)
-25 °C ... 75 °C T5 / II 2D / II 1D
(ANSI/UL 508/CSA
C22.2#14-10)
Ambient temperature range
Current rating I
i
: 60 ... 150
mA
-25 °C ... 50 °C (temperature class T6)
-25 °C ... 70 °C (temperature class T5)
-25 °C ... 70 °C (II 2D / II 1D)
Possible actuation magnets
304 200 00 V.
304 200 00 VH. (hygiene magnet)
304 200 00 VS. (magnet-strong)
304 200 00 SH. (hygiene magnet-
strong)