Date: 20.04.2016
GB
40/135
1.7 Cable specification
* The cable is halogen-free.
** The cable coating is halogen-free.
Follow the applicable installation advice when installing the
cables.
At ambient temperatures lower than -5 °C, ensure the cables
are properly supported.
Note The sensors are double insulated, therefore no protective
conductor is necessary.
Type
Operating
temperature
Voltage
rating
Capacitance/
inductance
PVC-UL
Y-UL 2517
-30 °C ... 105 °C
300 Volt 100 pF/m
0.7
H/m
Silicone
SiHSI *
-25 °C ... 180 °C
400 Volt 60 pF/m
1 nH/m
Silicone
SXCS
shielded *
-25 °C ... 180 °C
400 Volt 60 pF/m
1 nH/m
PUR
BOY11Y **
-40 °C ... 85 °C
250 Volt 100 pF/m
1 nH/m
PVC gray
Boflex-W
-40 °C ... 105 °C
300 Volt 115 pF/m
1 nH/m
PVC gray
LIYCY W
shielded
-40 °C ... 105 °C
250 Volt 100 pF/m
1 nH/m
PUR silicone free, UL
HK-SO-Li9Y11Y-OZ-
HF
-40 °C ... 85 °C
300 Volt 70 pF/m