Date: 20.04.2016
GB
35/135
* Optional, for intrinsically safe version:
blue cable coating
or
marked with blue heat shrink tubing
1.2 Electrical specification (sensors not
operated in intrinsically safe mode)
Sensor 671 *** M** **-**, 671 *** N** **-** (with potential
terminal)
* -25 °C ... 75 °C T5 / II 2D / II 1D
(ANSI/UL 508/CSA C22.2#14-10)
Ensure that the sum of all component currents does not
exceed the given current rating of the sensor.
Ensure that the maximum rated current per switching contact
does not exceed 75 mA.
ij
Others
Customer-specific
kl
Others
Extra cable length (standard: 1m)
Type
671 *** M** **-**
671 *** N** **-**
Voltage rating
( V AC/DC)
24
Rated current (mA), static
60
150
Power rating (W/VA)
5
5
Temperature class /
max. ambient temperature 2G
T5 / 85 °C*
T6 / 70 °C
T5 / 70 °C
T6 / 50 °C
max. ambient temperature 2D
85° C
70° C
Protection class
IP 68 10 bar (IEC 529)
Characteristic
Meaning