For category 1G and 2D:
Only use cables tested for electrostatic discharge.
When using a shielded line, the shielding must be factored
into the potential equalisation.
Additional advice for category 1G:
Use shielded cables.
Avoid subjecting the line to any intensive charging processes.
Permitted cables
Cables approved for 2D / 1D applications after electrostatic test:
Cables cleared for 1G after electrostatic test:
8
th
digit of part
numbering system
Cable
1
Boflex W (PVC gray) 2 x 0.75 mm² /
3 x 0.75 mm² / 4 x 0.75 mm²
2
SIHSI (silicone red) 2 x 0.75 mm² /
3 x 0.75 mm²
3
BOY11Y (PUR black) 2 x 0.75 mm² /
3 x 0.75 mm²
4
LIYCYW (PVC shielded) 2 x 0.75 mm² /
3 x 0.75 mm² / 4 x 0.5 mm²
U
Y-UL 2517 (PVC gray) 3 x 0.75 mm² /
4 x 0.75 mm²
L
HK-SO-Li9Y11Y-OZ-HF (PUR silicone
free) 4 x 0,75 mm²
8
th
digit of part
numbering system
Cable
4
LIYCYW (PVC shielded) 2 x 0.75 mm²
/ 3 x 0.75 mm² / 4 x 0.5 mm²
L
HK-SO-Li9Y11Y-OZ-HF (PUR sili-
cone free) 4 x 0,75 mm²