2.2.2 Safety-relevant data
Safety sensors type 671271*** **-**, 671V62*** **-**
Safety-relevant data
671271..0..-..
671V62..0..-..
B
10d
according to
EN ISO 13849-1
Appendix C
(at max. 20% contact load)
20,000.000
Service life in years
20
An individual sensor can be
used up to
1)
PL e (DIN EN ISO 13849-1)
SIL
CL
3 (IEC/DIN EN 62061)
1)
For this, at least the following
measures are required:
- Short circuit recognition
through differing voltages or
pulsed signals
- Two-channel structure
(see EN ISO 13849-1)
- Additional information
(see EN ISO 13849-2)