CLEARANCE OF NEEDLE GUARDS
7
2.7~3.4mm
2 mm
a
c
0~0.05mm
1. Remove: Mains lead - Needle plate.
2. Insert 2 new needles (
No.90
) in
"R1"
and
"R2"
positions.
3. Check height - clearance - angular position of lower looper.
4. Turn the handwheel towardas you and bring needle bar in its lowest position.
5. Loosen screws
"a"
.
6. Shift needle guard
"c"
back and forth to obtain a clearance of
0.05mm
between needle
guard
"c"
and needles, tighten both screws
"a"
.