Nominal power voltage
230 V~ +10% -15% 50/60 Hz
Max absorption power at 230 V (PS515)
600 mA
PS515 power output nominal voltage - type A power supply
14.4 V
⎓
Max current deliverable PS515 power supply
1.5 A
Ripple max PS515
100 mV p.p. with I = 1 A
Control panel operating voltage
10.5 V
⎓
to 16 V
⎓
Overload protection tripping current
16 V
⎓
Nominal current absorbed by control panel board at 12 V
⎓
(with relays energised, default condition)
85 mA stand-by with balanced inputs
Max current absorbed by the control panel board ( with relays de-energised)
65 mA with balanced inputs;
Installable battery
12 V
– 7.2 Ah
Nominal voltage of battery charger
note 1)
13.8 V
⎓
Max current supplied to charge battery
350 mA
Max time for recharging battery to 80%
24 hours
Battery flat threshold
11.5 V
Battery release threshold
10.5 V
Automatic test battery
every 24 hours (with mains)
Max current for external devices (keypads, sensors, sirens):
taken from +, +V1, +V2 terminals
Degree 3
– with ATS4 dialler and 60 hour autonomy
Degree 3
– with ATS4 dialler and 30-hour autonomy
note 2)
(total 220 mA, of which 85 mA for the control panel)
Degree 2
– with ATS2 dialler and 12 hour autonomy
(total 450 mA, of which 85 mA for the control panel)
CONFIGURATION NOT POSSIBLE
135 mA
365 mA
Nominal voltage on the +SR terminal
note 3)
14.4 V
⎓
Max current deliverable from the +SR terminal
200 mA (with overload protection)
Nominal voltage on the + terminal
13.8 V
⎓
±1.5%
Max current deliverable from + terminal
1100 mA (with overload protection)
Nominal voltage on the +V1 terminal
13.8 V
⎓
±1.5%
Max. current deliverable from +V1 terminal
750 mA (with overload protection)
Nominal voltage on the +V2 terminal
13.8 V
⎓
±1.5%
Max total current deliverable from the +V2 terminals
750 mA (with overload protection)
Ripple max on oSR + +V1 +V2 with flat battery
100 mV (0.7%)
Max current and voltage of relay contact switch of outputs U1 and U2
1 A
– 24 V
⎓
with resistive load
Max current deliverable from electric output U3
100 mA
Max current deliverable from electric outputs U4, U5, U6
10 mA
Tamperproof switch
1 A
– 24 V
⎓
Max total length of control panel-peripheral serial Bus line
400 m
Max length of the audio line (audio bus)
300 m with twin telephone line
Max length of the connection between each sensor or actuator and the control
panel
500 m
Max length of the connection between a fast sensor (roller, shock,...) and the
control panel
100 m
Max number possible code combinations
from 10,000 to 1,000,000
Number of possible combinations of DK50 electronic keys
more than 1099 billion
Number of possible combinations of DK30 proximity keys
more than 4 billion
Number of possible combinations of DK70 proximity keys
more than 4 billion
Programmable time entry
5 s to 5 minutes
Programmable exit entry
5 s to 5 minutes
Programmable alarm time
30 s to 15 minutes (default 3 minutes)
Programmable tamper alarm time
30 s to 15 minutes (default 3 minutes)
Failure signal
optical (LED) and electric for control panel battery low,
fuses, low power supply expansion boards
Type of memory for programming, Events log, and diagnose log maintenance Data Flash
Certified functioning time (EN50131
– Environmental class II, general internal) -10°C to +40°C
Average relative humidity during operation
75%
Storage temperature
-20°C to +60°C
Pollution degree
Grade 2
Overvoltage Category
CAT II
Degree of protection of casing
IP40/ IK06
Dimensions (W x H x D)
338 x 240 x 90 mm
Weight (without battery)
1400 g