102
MP500/4N-8-16 Installation
7.9
RESETTING FACTORY SETTINGS
The table below indicates the various possibilities for resetting the control panel and system devices to default values as needed.
The default values can be found in the
Programming Manual
.
Partial
reset
Global
reset
Reset
Installer,
Master, and
User codes
Reset
installer
hardware
code
Reset
hardware
factory
settings
Reset
devices
PARAMETERS IN THE CONTROL PANEL
MEMORY
Control panel programming
■
■
■
Device addresses
■
■
Event log
■
■
Installer Code
■
■
■
■
Tech. Manager Code
■
■
■
■
Master Code
■
■
■
User codes
■
■
■
Keys
■
■
PARAMETERS IN THE DEVICE MEMORIES
Number of the device
■
■
Device parameters
■
■
■
Table 11 - Variations of the configuration with reset
IMPORTANT!
The reset operations are irreversible and therefore once carried out, it become necessary to reacquire and/or
reprogram any devices involved.
The programming of the control panel consists in the configuration and the naming of inputs, outputs, times and partitions, the timing
programmer, the parameters, and the PSTN/GSM telephone numbers.
The event log can also be deleted from the Installer menu at «DIAGNOSE LOG». For more details, please see the
Programming
Manual
.
The keys can also be deleted individually from the Installer menu or from the Technical Manager at «SETTINGS». For more detai ls,
please see the
Programming Manual
.
To restore a keypad to Italian, it is necessary to access «MAINTENANCE» / «LINGUA-LANGUAGE» in the Installer menu.
The sequence is: <<
Installer Code>>
→
OK
→
Menu
→▲→
OK
→
Maintenance OK
«
LINGUA-LANGUAGE
» «
KP01:KP 01
» will appear on the display. Select the number of the key that you wish to reset to Italian and
press
OK
.
Use the ▼▲ keys to scroll the languages until you find « ITALIANO» and confirm your choice by pressing the
OK
key.
«
Download in progress >>>>...
» will appear on the display. when the download of the new language is complete, the message
«DOWNLOAD OK» will appear.
IMPORTANT!
For the Vocal Synthesis board it is not possible to restore the message to default.
7.9.1 Partial reset
Reset the control panel programming to default.
The following are not deleted: the Diagnose Log., the codes, the keys, and the device acquisitions.
To carry out the partial reset:
1. Select the item
«MAINTENANCE» / «PARTIAL RESET»
in the Installer menu and confirm with
OK
.
2. When asked
«ARE YOU SURE?»
press
OK
to confirm or
ESC
to cancel the operation.
3. The message
«PARTIAL RESET» «IN PROGRESS...»
will appear when
OK
is pressed and the buzzer will sound.
«MAINTENANCE» «PARTIAL RESET»
will appear then the operation is concluded.