MP500/4N-8-16 Installation
8 - TECHNICAL SPECIFICATIONS
8.1
MP500/4N CONTROL PANEL
Nominal power voltage
230 V~ +10% -15% 50/60 Hz
Max absorption power at 230 V (PS515)
600 mA
PS515 power output nominal voltage - type A power supply
14.4 V
⎓
Max current deliverable PS515 power supply
1.5 A
Ripple max PS515
100 mV p.p. with I = 1 A
Control panel operating voltage
10.5 V
⎓
to 16 V
⎓
Overload protection tripping current
16 V
⎓
Nominal current absorbed by control panel board with IL500-N at 12 V
⎓
(with relays energised, default condition)
(with relays de-energised)
75 mA stand-by with balanced inputs
65 mA with balanced inputs
Installable battery
12 V
– 7.2 Ah
Nominal voltage of battery charger (
Note 1
) 13.8 V
⎓
Max current supplied to charge battery
350 mA
Max time for recharging battery to 80%
24 hours
Battery flat threshold
11.5 V
Battery release threshold
10.5 V
Automatic test battery
every 24 hours (with mains)
Max current for external devices (keypads, sensors, sirens):
taken from +, +V1 terminals
Degree 2
– with ATS2 dialler and 12 hour autonomy
(total 450 mA, of which 75 mA for the control panel with ILT500-N)
375 mA
Nominal voltage on the + terminal
13.8 V
⎓
±1.5%
Max current deliverable from + terminal
1100 mA (with overload protection)
Nominal voltage on the +V1 terminal
13.8 V
⎓
±1.5%
Max. current deliverable from +V1 terminal
750 mA (with overload protection)
Ripple max on o +V1 with flat battery
100 mV (0.7%)
Max current and voltage of relay contact switch of outputs O1
1 A
– 24 V
⎓
with resistive load
Max current deliverable from electric output O2
100 mA
Tamperproof switch
1 A
– 24 V
⎓
Max total length of control panel-peripheral serial Bus line
400 m
Max length of the audio line (audio bus)
300 m with twin telephone line
Max length of the connection between each sensor or actuator and the control
panel
500 m
Max length of the connection between a fast sensor (roller, shock,...) and the
control panel
100 m
Max number possible code combinations
from 10,000 to 1,000,000
Number of possible combinations of DK50 electronic keys
more than 1099 billion
Number of possible combinations of DK30 proximity keys
more than 4 billion
Number of possible combinations of DK70 proximity keys
more than 4 billion
Programmable time entry
5 s to 5 minutes
Programmable exit entry
5 s to 5 minutes
Programmable alarm time
30 s to 15 minutes (default 3 minutes)
Programmable tamper alarm time
30 s to 15 minutes (default 3 minutes)
Failure signal
optical (LED) and electric for control panel battery low,
fuses, low power supply expansion boards
Type of memory for programming, Events log, and diagnose log maintenance Data Flash
Certified functioning temperature (EN50131
– Environmental class II, general
internal)
-10°C to +40°C
Average relative humidity during operation
75%
Storage temperature
-20°C to +60°C
Pollution degree
Grade 2
Overvoltage Category
CAT II
Degree of protection of casing
IP40/ IK06
Dimensions (W x H x D)
338 x 240 x 90 mm
Weight (without battery)
1400 g
For further information, see also paragraph
Note 1)
If the battery is not connected to the terminals of the connection cables, (red and black Faston) there is no power.