Page 14
EZS8WSLVP EZS8WSSVP LZS8WSLVP LZS8WSSVP
1000002160 (Rev. A - 11/14)
Error
Graphics Board
Displayed
Message
Alpha Board Displayed
Message
LED Board
Menu
Error Code
Display
Message Sent to Support
Action (See Notes)
Activation
Automatic
Reset Y
es/No
Notes
Evaporator
Thermistor Open Circuit
Maintenance
Maintenance
E001 SR
Refrigeration Error - 001 - Support Required
Display Error - Shut Down
Refrigeration - Send Error
Always On
No
Extremely high resistance detected
Evaporator
Thermistor Short Circuit
Maintenance
Maintenance
E002 SR
Refrigeration Error - 002 - Support Required
Display Error - Shut Down
Refrigeration - Send Error
Always On
No
No resistance detected
Evaporator
Thermistor Low
Temperature (V
ariable) -See note
Maintenance
Maintenance
E003 SR
Refrigeration Low
Temperat
ur
e
W
arning - 003 - Support
Required
Display Error - Shut Down
Refrigeration - Send Error
Always On - See
Note
No
Variable set temp
Condenser
Thermistor Open Circuit
Maintenance
Maintenance
E004
Refrigeration Error - 004 - Support Required
Have fan turn on/of
f with
compressor - Send Error
Always On
No
Extremely high resistance detected
Condenser
Thermistor Short Circuit
Maintenance
Maintenance
E005
Refrigeration Error - 005 - Support Required
Have fan turn on/of
f with
compressor - Send Error
Always On
No
No resistance detected
Condenser Over
Temperature
E006
Refrigeration W
arning - 006
Send Error
Always On
Ye
s
Variable set temp
Compressor Over
Temperature W
arning
E007
Refrigeration W
arning - 007
Send Error
Can be turned of
f/
Not used in initial product launch
Ye
s
Variable set temp
Compressor Over
Temperature Error
Maintenance
Maintenance
E008 SR
Refrigeration Error - 008 - Support Required
Display Error - Shut Down
Refrigeration - Send Error
Can be turned of
f/
Not used in initial product launch
No
Variable set temp
Too many compressor cycles in a timeframe (V
ariable)
E009
Refrigeration Error - 009 - Support Required
Send Error
Always On
No
Variable set value
Compressor runs but evaporator temperature does not drop in first
30 seconds
Maintenance
Maintenance
E01
1 SR
Refrigeration Error - 01
1 -
Support Required
Display Error - Shut Down
Refrigeration - Send Error
Always On
No
Use this for “T
oo many compressor
cycles in a timeframe (V
ariable)” too
Bottle Sensor Obstruction detected after 20 second timeout
Please Clear Bottle
Filling Area
Please Clear Bottle Filling Area
Display Error
Always On
Ye
s
IR board must be present (Automatic
detection via firmware)
Bottle Sensor Obstruction over “X” time
Maintenance
Maintenance
E012
Bottle Filling
Area Obstructed
-012
Display Error - Send Error
Always On
Ye
s
IR board must be present (Automatic
detection via firmware)
W
ater Filter 80% Used
Filter Status
Solid
Yellow
W
ater Filter Over 80% Used
Send Error (LED Status Solid Red / Graphics Display status)
Filtered unit only
Ye
s
NFC and LED or Graphics Display
and NFC boards must both be present
to designate the unit is a filtered unit.
(Automatic via firmware)
W
ater Filter 100% Used
Filter Status
Solid Red
Please Change W
ater Filter
Send Error (LED Status Solid Red / Graphics Display status)
Filtered unit only
Ye
s
NFC and LED or Graphics Display
and NFC boards must both be present
to designate the unit is a filtered unit.
(Automatic via firmware)
Filter missing from a filtered unit or non-compatible filter
Maintenance
Blinking
Red
E013
Filter Error -013 - No Filter or
Non-Compatible Filter
Display Error - Send Error
(LED Status Blinking Red
/ Graphics Display status)
Filtered unit only
Ye
s
NFC board must be present. (Automatic
via firmware)
NFC Board not detected on a filtered unit
Maintenance
Blinking
Red
E014
Filter Error - 014 - Filter Board Not Detected
Display Error - Send Error
Filtered unit only
Ye
s
LED board be present to designate
the unit is a filtered unit. (Automatic via firmware)
Note: Refrigeration Under
Temperature W
arning occurs when the
evaporator temperature reaches or goes below the variable set temperature for more than 30 seconds.
On the
Alpha Display
, Bottle count will display for 15 seconds with the
“Maintenance” message displaying for 1 second.
Note: Refrigeration Under T
emperature W
arning occurs when the evaporator temperature reaches or goes below the variable set temperature for more than 30 seconds.
On the
Alpha Display
, Bottle count will display for 15 seconds with the “Maintenance” message displaying for 1 second.
Troubleshooting Guide