Page 11
1000002160 (Rev. A- 11/14)
EZS8WSLVP EZS8WSSVP LZS8WSLVP LZS8WSSVP
Depress button for 3 seconds to activate main menu - release
Cycles through main menu items 2 seconds each for 3 cycles then exits menu unless selected.
Cycles through sub menu items 2 seconds each for 3 cycles then returns to main menu unless selected.
Selections are saved and exits menu when idle for 10 seconds
Top Level Menu
Action
Sub Menu 1
Action
Sub Menu/Action
Action
Sub Menu/Action
Action
Sub Menu/Action
Notes
End Action
Set Day/T
ime
Momentary
Drops to next level menu when selected
Day (Sunday - Saturday)
Momentary
Flash days of week on display waiting for signal of selection, 3 cycles through days and display goes back
to default.
Drops to next level menu when selected
Hour (12 Hour)
Momentary
Scroll hours from 1-12, 3 cycles through hours and display goes back to default.
Drops to next level menu when selected
Minute (0-60 in 5min increments)
Momentary
Scroll minutes from 0-60 in 5 minute increments, 3 cycles through minutes and display goes back to de
-
fault.
Drops to next level menu when selected
AM/PM
Momentary
Scroll
AM and PM, 3 cycles through
AM/PM and display
goes back to default.
Returns to main menu
Filter Unit?
Momentary
No
Momentary
Turn of
f filter status and
errors
No filter unit - LED board not used - Graphics Display does not show status - Error codes related to filter
turned of
f.
Returns to main menu
Ye
s
Momentary
Turn on filter status and
errors
Filter unit has default config on - default config has read/ write to filter
, LED or Graphics stat display
, filter error
capability
.
Returns to main menu
Refrigeration Unit?
No
Momentary
Turn of
f all regrigeration
controls
Refrigeration of
f
Returns to main menu
Ye
s
Momentary
Set unit to operate as refrigerated unit
Refrigeration on
Returns to main menu
Flow Rate?
High
Momentary
Set W
ater Rate 1.5 Gal/Min
Set water rate setting to 1.5gal/min.
Returns to main menu
Low
Momentary
Set W
ater Rate 1.1 Gal/min
Set water rate setting to 1.1gal/min.
Returns to main menu
W
ater T
emperature
Momentary
Cold
Momentary
Set to “Cold”
Temperature
Approx 58° F
Returns to main menu
Colder
Momentary
Set to Default
Temperature
Approx 54° F
Returns to main menu
Coldest
Momentary
Set to defined “Coldest” Temperature
Approx 50° F
Returns to main menu
Backlight Setting
Momentary
Set Backlight/Alcove light in idle mode
Momentary
Backlight settings are: 1=25%, 2=50%, 3=75% and 4=100%
1 (= 25%)
Momentary
Returns to main menu
2 (=50%)
Momentary
Returns to main menu
3 (=75%)
Momentary
Returns to main menu
4 (=100%)
Momentary
Returns to main menu
Energy Save Mode
Momentary
O
ff
Momentary
Default operation
Unit runs with control board controlled refrigeration on always.
Returns to main menu
On
Momentary
Set Energy Save Schedule
Unit refrigeration is shut of
f based on schedule.
Drops to next level menu when selected
Select W
eekdays (default when
no time is selected =
Always of
f)
W
eekdays (Monday - Friday) schedule settings
Drops to next level menu when selected
Momentary
Select
Time on
24 Hours - 1-12AM and 1-12 PM
Drops to next level menu when selected
Momentary
Select
Time of
f
24 Hours - 1-12AM and 1-12 PM
Drops to next level menu when selected
Select W
eekend
W
eekend (Saturday and Sunday) scheduled settings.
Drops to next level menu when selected
Momentary
Select
Time on
24 Hours - 1-12AM and 1-12 PM
Drops to next level menu when selected
Momentary
Select
Time of
f
24 Hours - 1-12AM and 1-12 PM
Returns to main menu
View Error Codes
Momentary
Flashes Error Codes
2 seconds each / 3 cycles through codes
Returns to main menu
Clear Error Codes
Momentary
Are you sure?
Momentary
Yes - Clear error modes
Clears all error codes in control board memory
.
Exit Menu
Programming Instruction