P 2500 - P 5000
29
Boom length [in]
Model
78.74 98.41 118.11 137.80 157.48 177.17 196.85
articulated
boom
F1.1
F1.1
P 2500 with
round boom
2x
F1.1
2x
F1.1
---
---
---
---
---
P 3000
2x
F1.1
2x
F1.1
3x
F1.1
---
---
---
---
P 3000 with
articulated
boom
2x
F1.1
3x
F1.1
3x
F1.1
---
---
---
---
P 3000 with
round boom
2x
F1.1
2x
F1.1
2x
F1.1
---
---
---
---
P 3500
2x
F1.1
2x
F1.1
3x
F1.1
4x
F1.1
---
---
---
P 3500 with
articulated
boom
2x
F1.1
3x
F1.1
3x
F1.1
4x
F1.1
---
---
---
P 3500 with
round boom
2x
F1.1
2x
F1.1
2x
F1.1
3x
F1.1
---
---
---
P 4000
2x
F1.1
2x
F1.1
3x
F1.1
3x
F1.1
2x
F1.2
---
---
P 4000 with
swinging
support
---
---
---
2x
F1.2
2x
F1.2
---
---
P 4000 with
articulated
boom
2x
F1.1
2x
F1.1
3x
F1.1
4x
F1.1
2x
F1.2
---
---
P 4000 with
round boom
2x
F1.1
2x
F1.1
2x
F1.1
3x
F1.1
3x
F1.1
---
---
P 4000 with
round boom
and with
swinging
support
---
---
---
3x
F1.1
2x
F1.2
---
---
P 5000
---
---
---
2x
F1.2
3x
F1.2
3x
F1.2
4x
F1.2
P 5000 with
swinging
support
---
---
---
3x
F1.2
3x
F1.2
3x
F1.2
4x
F1.2
Table 6
Pressure spring type F1.1 = Balancing spring
Wire diameter 0,2in
For barriers up to 137.79in boom length
Summary of Contents for P 2500
Page 14: ...P 2500 P 5000 13 4 Declaration of incorporation Drawing 2 ...
Page 20: ...P 2500 P 5000 19 7 2 Mounting dimensions Drawing 3 ...
Page 47: ...P 2500 P 5000 46 8 4 Circuit diagram Drawing 34 ...
Page 48: ...P 2500 P 5000 47 Drawing 35 ...
Page 49: ...P 2500 P 5000 48 Drawing 36 ...
Page 50: ...P 2500 P 5000 49 Drawing 37 ...
Page 51: ...P 2500 P 5000 50 Drawing 38 ...
Page 52: ...P 2500 P 5000 51 Drawing 39 ...
Page 55: ...P 2500 P 5000 54 10 Layout exploded drawing Drawing 41 ...