P 2500 - P 5000
42
DANGER!
Danger through voltage!
Danger of an electric shock!
Observe the following connection instructions.
Connection instructions:
For a permanent electrical installation please observe the country-specific
regulations.
The
connection terminals
are designed for a rated cross-section per
terminal of
AWG 22 to AWG 14
.
The supply lead cross-section used has to be suitable for the load and
comply with the local regulations.
DANGER!
Danger through voltage!
Danger of an electric shock!
Connect the protective conductor of the mains lead
directly to the protective conductor terminal (PE) at the
barrier housing.
1. For the connection to the terminals and the protective conductor terminal
(PE) the flexible mains lead must have the following dimensions:
Drawing 31
1 Lead N, length a = 1.81in incl. conductor sleeve
2 Lead L1, length b = 2.17in incl. conductor sleeve
3 Lead PE, length c = 11.81in with eyelet for M6
When using a solid mains lead, use the dimensions according to the above
drawing.