FITTING THE DOOR HANDLES
The handles are fitted to the infill panel on each door (choose between 1st or 2nd panel down). Po-
sition the handle centrally, and mark the hole position. Drill 7mm diameter holes (2 holes per
door), then fit the handles, and secure with a nut and bolt.
FITTING THE DOOR LOCK
The door lock must be fitted after the doors are in position.
(Key point).
Undo the ring bolt from
the door lock, and insert the barrel through the hole in the panel from the outside. Reattach the ring
bolt to the barrel on the inside, and tighten.
Now attach the cam lever, washer and screw to the door lock from the inside position of the door.
The lock will turn through 90 degrees both ways, so you must ensure the cam (when fitted) is
pointing skywards (unlock position) and horizontal (locked position).
Now using a cropped head bolt, attach the domed pin to the bolt channel of the handed door post
on the left hand door (viewed from outside). Move the pin up or down in the channel so that the
notch on the cam locates comfortably when horizontal. Tighten all components.