5
USER MANUAL
RPS/M/1K
Elettrotest S.p.A. P.zza R. Riello, 20/B - 45021 Badia Polesine ( RO ) - tel. +39 0425 53567 - Fax +39 0425 53568
e-mail:
http:
62000582 Rel.1.0 – 15/03/2018
1.6.
GENERAL PERFORMANCES
All the following features are valid in the normal operation mode. They are not valid during the
output current limitation.
1.7.
GENERAL SPECIFICATIONS
PARAMETER
VALUE
Output frequency range
DC/ 10Hz - 80Hz
Frequency resolution
0.02Hz
Frequency precision and time stability
100ppm
Output voltage at constant power
300V
Output voltage resolution
0.025% f.s. (12 bit su f.s.)
Operating temperature of function
0°C - 35°C
1.8.
MAXIMUM OUTPUT CURRENT
PARAMETER
VALUE
Distortion of the output waveform
<0.3%
Stability of the output voltage
<0.1%
Accuracy of the output voltage
<0.5%
Recovery time of the output waveform
<10ms
Recovery-time of the output voltage
<10ms
Maximum compensated drop on wires
5% f.s.
Recovery-time of drop on wires
<200ms.
RPS/M/1K
REGIME CONTINUO/CONTINUOUS OPERATION
CORRENTE MASSIMA\MAX CURRENT
POTENZA MASSIMA\MAX POWER
PORT
DC 50 Hz 60 Hz LOAD
PORT
DC
50 Hz
60 Hz LOAD
300
-
2,7 A 2,6 A
CAP.
300
-
811 VA 768 VA CAP.
300
-
4,1 A 4,3 A
IND.
300
-
1235 VA 1277 VA IND.
300
3,4 A 3,3 A 3,3 A
RES.
300 1020 VA 1001 VA 991 VA RES.
REGIME IMPULSIVO (MAX 3 SECONDI)/ IMPULSIVE OPERATION(MAX 3 SECONDS)
CORRENTE MASSIMA\MAX CURRENT
POTENZA MASSIMA\MAX POWER
PORT
DC 50 Hz 60 Hz LOAD
PORT
DC
50 Hz
60 Hz LOAD
300
-
6,2 A 6,1 A
CAP.
300
-
1862 VA 1820 VA CAP.
300
-
7,6 A 7,8 A
IND.
300
-
1235 VA 2329 VA IND.
300
6,9 A 6,9 A 6,9 A
RES.
300 2064 VA 2064 VA 2059 VA RES.