Elettrotest S.p.A. P.zza R. Riello, 20/B - 45021 Badia Polesine ( RO ) - tel. +39 0425 53567 - Fax +39 0425 53568
e-mail:
http:
62000582 Rel.1.0 – 15/03/2018
Furthermore, RPS can bear a short-circuit for an indefinite time without suffering any
consequence.
ATTENTION !!!!
THE OUTPUT OF RPS IS NOT ISOLATED RESPECT TO THE MAIN POWER SUPPLY
NONE OF THE TWO OUTPUT PHASES CAN BE CONNECTED TO THE GROUND
1.3.
FREQUENCY OUTPUT
RPS allows the regulation of the output frequency from 10 Hz to 80 Hz. The output frequency can
be adjusted with continuity into the regulation range and it has a stability of 0.01% regards to set
frequency.
1.4.
USER INTERFACE
RPS can be controlled only through copyrighted serial communication protocol.
RPS allows various usage selections: wires drop compensation, working frequency, output DC,
output AC.
RPS gives the user clear information on the status of the output.
It is monitored both the set voltage and the set frequency. The output voltage can be remotely
read with a precision of 0.3%.
The user is also warned in case of overcurrent obtainable by the RPS, or in case of high loss on the
wires, that should not exceed 5% of the set voltage.
1.5.
MODELS
The models are different depending on the rated power and the supply mode (single phase or
three phase with neutral).
MODELS
NOMINAL
POWER
SUPPLY
VOLTAGE
WEIGHT
INPUT
CURRENT
DIMENSIONS
A, L, P mm
RPS/M/1K
1.000VA
230Vac ±10%
1PH
12 kg
8.5A
2U : 84 TE :
440