33
33
closed anyway. It turns off only when the gate is totally closed.
This warning signal is not enabled during the programming procedures.
N.B.: 3W Max. If you overuse the push button panels or the lamps,
the control board logic system may be compromised,
resulting into a possible operation block.
T
ECHNICAL DATA
- Moisture
< 95% without condensation
- Power supply voltage 230V~ ±10% (on request
120V±10% )
- Frequency
50/60 Hz
- Battey supply
20-24,5Vdc
- Weight without battery
kg 3,0
- Power transformer 130VA - V primary 230 Vac - V
secondary 18Vac
- Absorption max
25 mA
- Transient power mains drops
100ms
- Max. capacity of the warning light - gate open - 12Vdc
3
W
(corresponding to 1 3W lamp
or to 5 LEDS with 2,2 kΩ
resistance In series)
- Max load flasher
24Vdc 20W
- All the inputs must be used as clear contacts because the power
supply is generated inside (safe power) the control panel, and it has
been laid down in such a way to guarantee a double or strengthened
insulation in relation to the parts with dangerous power.
- Eventual external circuits connected to the outputs of the control
board or of the expander card must be carried out making sure that a
double or strengthened insulation is used in relation to parts with
dangerous power.
- All inputs are run by a programmed integrated circuit which does a self
check every time it starts operating.