26
26
INSTALLATION PRINCE
GG
BB
COMMAND TYPE
USE OF THE SHUTTER
Skilled persons
Skilled persons
Unrestricted use
(out of public area*)
(public area)
with manned operation
A
B
with visible impulses
C
C
C and D
(e.g. sensor)
with not visible impulses
C
C and D
C and D
(e.g. remote controldevice)
automatic
C and D
C and D
C and D
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated), like
code ACG2020
B: Key selector with manned operation, like code ACG1010
C: Safety edges or Sensor able to detect an obstacle (encoder PRINCE 24V PLUS)
and/or other safety devices to keep thrust force within the limits of EN12453
regulation - Appendix A.
D: Photocells, like code ACG8026
Parts to install meeting the EN 12453 standard
P
RE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be flexible
during the movement and must move without frictions.
Before the installation of PRINCE, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown in Fig. 1.
N.B.:
Gate features must be uniformed with the standards and laws in force.
The door/gate can be automated only if it is in a good condition and
its conditions comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in accordance
with EN 12453 norm (for instance; by preventing the operation of the motor
when the pedestrian opening is opened, by installing a safety microswitch
connected with the control panel).
E
MERGENCY RELEASE
To move the gate manually it is necessary to release the operator inserting
the special key and
turning it 90° in the anti-clockwise sense
(Fig. 3).
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for the
operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390N for
doors/gates for commercial and industrial sites (values indicated in 5.3.5 of
the EN 12453 norm).
F
IXING THE ACTUATOR ATTACHMENT TO THE COLUMN
To obtain a correct movement of the leaf gate it is necessary to respect the
measures.
In case an iron pillar is available, weld the bracket straight to it.
In case you need to fix the bracket onto a concrete pillar, use the fixing plate
as shown in picture 4, to be fastened with 4 Fischer screws of Ø 8 mm.
In the case you have a wall parallel with the open gate, you must provide a
niche in which to place the operator.
F
IXING THE ACTUATOR ATTACHMENT TO THE GATE
Then weld the second bracket to the gate (pictures 6,7)
Make sure to stick to the measures mentioned in the table below during
installation
Fix the PRINCE and try several times to open and to close the gate,
controlling that the screwcover does not touch the moving gate.
3
5
6
4