30
VENTING
Element4 Gas Fireplaces
European
Home
.com
As previously noted, restrictors must be fitted in some configurations. Use the table below to determine which restrictor may be
needed with your venting configuration. The restrictors are shown in Figure 25.
With a Horizontal (Wall) Termination
Vertical section is less than 391/2”/1
m
no restrictor required
Vertical section is between 391/2”/1
m
to 9’10”/3
m
35
mm
restrictor
-----------------------------------------------------------------------------------------------
With a Vertical (Roof) Termination
Total rise is less than 6’6”/2
m
35
mm
Total rise is greater than 6’6”/2
m
60
mm
The restrictor for all fireplace models installs at the very bottom of the outlet collar. Attach the appropriate restrictor to the
bottom of the outlet collar as shown in Figure 26 using the screws provided.
Table 6
Restrictors by Vent Configuration
INSTALLING A RESTRICTOR
Figure 25
35
mm
60
mm
Figure 26
RESTRICTORS