15
CLEARANCES
Element4 Gas Fireplaces
European
Home
.com
Figure 7
Plan View - Modore 95
Figure 8
Front Elevation View - Modore 95
Figure 9
Side Elevation View - Modore 95
MODORE 95
MODORE 95
Figures 7* through 9* show (in yellow) the clearances to
combustible material which
must
be maintained.
No material of any kind is allowed between the
bottom of the support feet and the bottom of the
firebox (shown in red).
No material of any kind is allowed within 2”/50
mm
from the top of the fireplace (shown in red).
No material of any kind is allowed within 2”/50
mm
from the metal sides the fireplace (shown in red).
Facing material should be installed against the outer
frame of the fireplace, with an 1/8” vertical clearance to
allow for heat expansion.
*drawings not to scale
11”
280 mm
11”
280 mm
11”
280 mm
11”
280 mm
11”
280 mm
11”
280 mm
26”
660 mm
26”
660 mm