16
CLEARANCES
Element4 Gas Fireplaces
European
Home
.com
Figure 10
Plan View - Bidore 95
Figure 11
Front Elevation View - Bidore 95
Figure 12
Side Elevation View - Bidore 95
11”
280 mm
11”
280 mm
11”
280 mm
11”
280 mm
26”
660 mm
26”
660 mm
Figures 10* through 12* show (in yellow) the clearances
to combustible material which
must
be maintained.
No material of any kind is allowed between the
bottom of the support feet and the bottom of the
firebox (shown in red).
No material of any kind is allowed within 2”/50
mm
from the top of the fireplace (shown in red).
No material of any kind is allowed within 2”/50
mm
from the metal sides the fireplace (shown in red).
Facing material should be installed against the outer
frame of the fireplace, with an 1/8” vertical clearance to
allow for heat expansion.
*drawings not to scale
BIDORE 95
BIDORE 95