Operating Guide
PSI 8000 3U HS PV Series
Date: 20-05-2016
Using the power supply
Notifications of the set/actual comparison
Example: The step from a lower set value to a higher set value
was not performed within the settling time
Tsr.
The supervi-
sion error is then notified as alarm, warning or signal.
U
or
U or
U
Depending on the configuration of
Step response,
notifications for the current (
I
) are alternatively displayed.
Example: The step from a higher set value to a lower set value
was not performed within the settling time
Tsf.
The supervi-
sion error is then notified as alarm, warning or signal.
U
or
U
or
U
Depending on the configuration of
Step response,
notifica
-
tions for the current (
I
) are alternatively displayed.
Part 2: The menu
Options
The menu entry
Options
+
leads you to following menu selection:
Reset configuration
Enable PV mode
Enable R mode
Setup lock
7.7
Reset to default configuration
You can reset all modifications of the setup to the default setup
(the state the unit had when it was delivered).
After selecting the corresponding menu entry you will be
prompted again to submit the choice to reset your current,
personal configuration.
Attention!
Even if the device configuration has been locked by a PIN
it will be unlocked and reset with this action!
Reset configu
Are you sure ?
Default:
NO
= YES
All modifications of the default setup are reset
= NO
No change
7.8 Activating the photovoltaics feature
Enable PV mode +
PV mode = {enabled | disabled}
With setting
enabled
, the hardware and software functionality of
the photovoltaics feature is enabled. This setting is permanent
until altered. Active PV functionality is indicated in the main dis-
play with text
PV
left to the power set value. About the principle
of the solar panel simulation of the PV feature see section „11.
Note
Activation of operation mode U/I/R will automatically reset
PV mode
to
disabled
. As long as U/I/R is activated, the PV
feature can not be enabled. Also see
7.9 Unlocking the U/I/R mode
The U/I/R operation mode can only be used after it was unlocked
with a PIN code in menu
Options
(also see section „14.3.
Option: Internal resistance“):
Enable R mode +
Activate R mode via pin code:
The code to use here is not for free and and can be obtained
from your device supplier. After it has been unlocked, the status
can be verified in the menu
Options
:
R mode available:
YES
The U/I/R operation mode is unlocked and can
be used
NO
U/I/R mode not enabled yet
Before the U/I/R mode can be used, it has to be activated in the
profile (see „7.1. Defining operation parameters“
). The resist-
ance set value then becomes adjustable in the main operation
display and goes from 0Ω up to R
Nom
, which is defined as
20 * U
Nom
÷
I
Nom
.