43
Operating Guide
PSI 8000 3U HS PV Series
EN
Date: 20-05-2016
About the device
2.2
Device specifications
* Related to the nominal value, the accuracy defines the maximum allowed deviation between set value and actual value.
Example: a 80 V model has min. 0.2% voltage accuracy. This is 160 mV. When setting a voltage of 5 V and with an allowed maximum deviation of 160 mV, the result-
ing actual value could be between 4.84 V and 5.16 V.
** Enclosure dimensions only, not overall dimensions
*** MPP value: HF 0...20 MHz, RMS value: LF 0...300 kHz
**** Unlockable option
PSI 8600-70 3U HS PV
PSI 81000-30 3U HS PV
PSI 81500-30 3U HS PV
Mains input
Input voltage range
340…460V AC
340…460V AC
340…460V AC
Required phases
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
Input frequency
45…65Hz
45…65Hz
45…65Hz
Input fuse
6x T16A
4x T16A
6x T16A
Input current
max. 28A
max. 28A
max. 28A
Power factor
> 0.99
> 0.99
> 0.99
Output - Voltage
Nominal voltage U
Nom
600V
1000V
1500V
Adjustable range
0V…U
Nom
0V…U
Nom
0V…U
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.02%
< 0.02%
< 0.02%
Stability at 0…100% load
< 0.05%
< 0.05%
< 0.05%
Ramp-up time 10...90% at 100% load
max. 30ms
max. 30ms
max. 30ms
Ripple ***
< 400mVpp
< 80mVrms
< 800mVpp
< 200mVrms
< 1000mVpp
< 350mVrms
Accuracy *
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
100mV
1V
1V
Remote sense compensation
max. 18V
max. 20V
max. 30V
Overvoltage protection threshold (adjustable)
0…660V
0…1100V
0…1650V
Output - Current
Nominal current I
Nom
70A
30A
30A
Adjustable range
0…I
Nom
0…I
Nom
0…I
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.05%
< 0.05%
< 0.05%
Stability at 0…100%
∆
U
OUT
< 0.15%
< 0.15%
< 0.15%
Ripple ***
< 30mApp
< 12mArms
< 22mApp
< 11mArms
< 19mApp
< 13mArms
Accuracy *
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
10mA
10mA
10mA
Transient recovery time 10….90% load
< 2ms
< 2ms
< 2ms
Output - Power
Nominal power P
Nom
15000W
10000W
15000W
Nominal power at derating
0...P
Nom
0...P
Nom
0...P
Nom
Accuracy *
≤
2%
≤
2%
≤
2%
Resolution of display
0.01kW
0.01kW
0.01kW
Efficiency
95.20%
95.50%
95.50%
Output - Internal resistance ****
Max. adjustable resistance
171.4
Ω
666.7
Ω
1000
Ω
Accuracy
< 2%
< 2%
< 2%
Resolution of display
100m
Ω
100m
Ω
1
Ω
Regulation time of set value to actual val.
~ 2s
~ 2s
~ 2s
Miscellaneous
Ambient temperature
0…50°C
0…50°C
0…50°C
Storage temperature
-20…70°C
-20…70°C
-20…70°C
Humidity rel.
< 80%
< 80%
< 80%
Dimensions (WxHxD) **
19" 3U 595mm
19" 3U 595mm
19" 3U 595mm
Weight
33kg
25.5kg
33kg
Redundancy
no
no
no
Isooutput to enclosure
1000V DC
1500V DC
2000V DC
Isolation -output to enclosure
Isolation input to output
Cooling
Safety
EMC standards
Overvoltage class
Protection class
Pollution degree
Operational altitude
Series operation
Master-Slave
Parallel operation
Master-Slave
Analogue programming
Isolation voltage
Input range
Accuracy
Input impedance
Digital programming
Article number
09901444
09901438
09901439
Built-in interface: 1500V / Interface card IF-A1: 2000V
53kOhm
≤
0.2%
0…5V or 0…10V, selectable
2
by fans, air inlet on the front, air exhaust on the rear
EN 60950
EN 61326, EN 55022 Class A
2
300V DC
Via pluggable interface cards: RS232, USB, CAN, GPIB, Ethernet
no
possible (with restrictions)
yes, with current distribution via Share bus
Via built-in isolated analogue interface or pluggable analogue interface card
no
2500V DC
<2000m
1