background image

User Manual

Intelligent Power 
System (iPS)

iPS-M S series Power System

Summary of Contents for iPS-M S Series

Page 1: ...User Manual Intelligent Power System iPS iPS M S series Power System ...

Page 2: ...mity FCC Class B Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the inst...

Page 3: ...arnings Cautions and Notes Packing List Before setting up the system check that the items listed below are included and in good condition If any item does not accord with the table please contact your dealer immediately iPS M series battery system x 1 4 PIN Ring Terminal cable x 1 4 PIN DC Jack cable x 1 6 PIN Remote control cable x 1 RJ45 RS232 console cable x 1 Warranty card x 1 Warning Any chan...

Page 4: ...ing system version application software etc A complete description of the problem The exact wording of any error messages This equipment is a source of electromagnetic waves Before use please make sure that there are not EMI sensitive devices in its surrounding which may mal function therefore Warning To prevent electric shock turn off AC power or unplug AC power cord before remove cover Caution 1...

Page 5: ...ource is correct before connecting the equipment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening Th...

Page 6: ...uthorization of the manufac turer 2 To avoid risk of electric shock this equipment must only be con nected to a supply mains with protective earth 3 To prevent electric shock turn off AC power or unplug AC power cord before remove cover 4 To disconnect this product from the mains supply disconnect the mains plug from the socket outlet The power supply is regarded as part of this equipment Caution ...

Page 7: ...aphical Symbols IEC 60878 and ISO 3864 B 3 6 Warning dangerous voltage ISO 7000 0434 Attention consult ACCOMPANYING DOCUMENTS ISO 7000 1641 Follow operating instructions or Consult instructions for use IEC 60417 5009 SANDY BY IEC 60417 5031 Direct current ...

Page 8: ... from damage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive elec tronic components ...

Page 9: ...ote Control 7 2 3 Battery Charging 7 Figure 2 4 Connecting the AC power cord with iPS M battery 7 Figure 2 5 AC power cord connecting and power switch on 7 Figure 2 6 AC power switch on 8 Figure 2 7 Connecting the remote control 8 Figure 2 8 Power ON battery 8 2 4 Battery Discharging 9 2 4 1 Device Connection 9 Figure 2 9 Battery power off 9 Figure 2 10Cable connection 10 2 4 2 Discharging Time Es...

Page 10: ...iPS M S series User Manual V A1 x ...

Page 11: ...Chapter 1 1 General Information ...

Page 12: ...OD 80 2000 cycles DOD 80 1000 cycles Charge Time 3hr DOD 100 1 5hr DOD 100 Input Voltage 100 240Vac 50 60H Max 4 5A DC Output Voltage System 1 19 Vdc Max 6A System 2 12 Vdc Max 5A Charging Status Indicators LEDs with continuous readout intelligent software I O Ports DC Output Inter face DC Jack 4 pin mini lock din Communication Interface RS 232 Environment Vibration 5 500Hz 1G Cooling System Fanle...

Page 13: ...ristics Dimensions L x W x H 80 x 48 x 14 mm 3 1 x 1 8 x 0 5 inch Weight 0 3kg Display Controller Power Button Battery power button LED Display LED Indicator Category Attribute iPS REMT Physical Characteristics Dimensions L x W x H 54 x 23 x 12 mm 2 1 x 0 9 x 0 4 inch Weight 0 4kg I O ports DC In 12 24Vdc 8 3A DC Out Mode 1 12Vdc 6A Mode 2 15Vdc 5A Mode 3 16Vdc 5A Mode 4 19Vdc 4A ...

Page 14: ...iPS M S series User Manual V A1 4 1 5 Dimensions ...

Page 15: ...Chapter 2 2 Getting Started ...

Page 16: ...starting to use IPS take a moment to become familiar with the functions of connectors switches and ports which are illustrated in the figures below Figure 2 1 I O Ports and AC Connector The front side view figure 2 2 Figure 2 2 Front and Top View with AC Switch AC On Off Switch ...

Page 17: ... Power System you MUST perform a battery charge before providing power to other devices To do a battery charge connect the AC power cord and turn on the AC power switch beside the AC IN connector on the front side Also connect the remote control to the battery and press the power on button press and hold for at least 7 seconds to turn on power Figure 2 4 Connecting the AC power cord with iPS M bat...

Page 18: ...Manual V A1 8 Figure 2 6 AC power switch on Figure 2 7 Connecting the remote control Figure 2 8 Power ON battery Turn on switch Connect remote control Press the power button and hold for 7 seconds to turn on battery power ...

Page 19: ...6A 114W System 2 12V x 5A 60W Maximum output is around 174W 2 4 1 Device Connection Before connecting equipment to iPS M power system turn off battery power from the remote control first Then connect the cable to the battery system and equipment Figure 2 9 Battery power off Caution After purchasing the new iPS M power system you must charge the battery to 100 which keeps the battery cell in active...

Page 20: ...the remote control again and the battery is ready to supply DC power to device 2 4 2 Discharging Time Estimation To estimate discharging time you must need to know the power consumption of the loader PC or Device For example assuming power consumption of the loader is 40Wh discharging time for different capacities of iPS M batteries is listed following To device To battery Model Discharging Time E...

Page 21: ...n battery capacity is 0 the battery system shuts down automatically 2 Turning iPS on when battery capacity is lower than 10 If the battery capacity is less than 10 initially when you press the power on button on the remote control to turn on the battery the Red LED on the remote will keep flashing and a warning beep sound is triggered The beeping sound will continue until AC power is plugged in Wh...

Page 22: ... Manual V A1 12 2 5 Battery Pack Replacement iPS M power system allows to do battery pack replacement in just 4 easy steps 1 Turn AC power switch off 2 Remove top cover screws and top cover Turn off switch Turn off switch ...

Page 23: ...anual V A1 Chapter 2 Getting Started 3 Remove screws on battery pack holder 4 Disconnect battery cell cable and system cable to remove old battery cell and replace new one 5 Reverse above steps to reassemble the battery system ...

Page 24: ...iPS M S series User Manual V A1 14 ...

Page 25: ...Chapter 3 3 Battery Maintenance ...

Page 26: ... recharged within 48 hours 2 days to main tain the battery life 3 2 Storing the Battery If the battery system or battery pack is going to be stored in a warehouse for a long time the following tasks need to be performed 1 When battery is new recharge it to 100 immediately before moving to the warehouse 2 Before storing the battery and leaving it in idle status it must be recharged to 100 3 If batt...

Page 27: ...battery system follow these recovery steps 1 Press the reset button once when battery power is down remote LED off 2 Press power button hold for 7 seconds on Remote Control to power on the battery 3 When the LED lights up again the battery system is recovered Warning When battery is going to be stored for a long time make sure to recharge it to 100 capacity If stored in a warehouse over 1 year you...

Page 28: ...iPS M S series User Manual V A1 18 ...

Page 29: ...Chapter 4 4 EMC Table ...

Page 30: ...ent specified below The customer or the user of the model IPS M power system should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic envi ronment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material t...

Page 31: ... for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Mains power quality should be that of a typical commercial or hospital environment If the user of the model IPS M Bat tery requires continued operation during power mains interruptions it is recommended that the model IPS M Battery be powered from an uninter ruptible power supply or another ...

Page 32: ...ations are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2014 ...