210-10 ADL
58/62
599 75 60-77
Steps
Procedure
7. Remove connection pipe clamp and evaporator assy
Remove the screws fixing connection pipe clamp,
to remove the clamp. Remove the two screws
connecting evaporator angle support and chassis,
remove the screws fixing evaporator assy and
motor clamp, loosen the clamp, slightly regulate
the evaporator connection pipe position, to
remove the evaporator.
8. Remove motor clamp
Remove the screws fixing motor clamp, to remove
the clamp.
Steps
Procedure
9. Remove motor and cross fan blade
Remove the screws connecting cross fan blade and
motor, to remove the motor and cross fan blade.
screw
connection
pipe clamp
evaporator
assy
screw
clamp
screw
motor clamp
screw
motor
cross fan blade