210-10 ADL
57/62
599 75 60-77
6. Remove electric box assy
Loosen the clasp of electric box cover; remove the
electric box cover; remove the tube temperature
sensor; remove the 3 earthing wire screws of
evaporator and then remove the connection screw
of electric box and chassis.
Remove the 2 connection screws of electrostatic
deduster and evaporator and then remove the
electrostatic deduster.
Remove the cold plasma generator from the
evaporator; disconnect the connection wire of cold
plasma generator and mainboard to remove the
cold plasma generator.
。
Disconnect each wiring terminal with mainboard
to remove the electric box.
motor connection
terminal
step motor
connection
terminal
clamp
electric box
cover 1
scre
w
earthin
g screw
indoor tube
temp. sensor
cold plasma generator
screw