210-10 ADL
31/62
599 75 60-77
Diagnosis and Solution:
Error Code
Name of malfunction
Display
of indoor
unit
Display of lamp (the times of blinking)
Page
NO.
Indoor
Outdoor
Running
Cooling
Heating
Yellow
Red
Green
Anti-freezing protection
E2
2
3
P45
System block or refrigerant leakage
E3
3
9
P48
Compressor exhaust high temperature
protection
E4
4
7
P48
AC over-current protection
E5
5
5
P45
Communication failure between indoor unit and
outdoor unit
E6
6
OFF
P44
P39
Anti-high temperature protection
E8
8
6
P48
H4
6
No feedback of indoor fan motor
H6
11
P35
P36
Jumper cap malfunction protection
C5
15
P37
P38
Indoor unit and outdoor unit doesn't match
LP
19
16
P47
Outdoor DC fan motor malfunction
L3
23
14
Power protection
L9
20
9
Gathering refrigerant
Fo
1
1
Indoor ambient sensor open or short circuit
F1
1
P33
P34
Indoor tube sensor open or short circuit
F2
2
Outdoor ambient sensor open or short circuit
F3
3
6
P46
Outdoor tube sensor open or short circuit
F4
4
5
P46
Exhaust sensor open or short circuit
F5
5
7
P46
Overload limit / drop frequency
F6
6
3
Over current limit / drop frequency
F8
8
1
High exhaust temperature limit / drop frequency
F9
9
2
Anti-freezing limit / drop frequency
FH
2
2
4
Defrosting
H1
1
2
Compressor overload protection
H3
3
8
P49
IPM protection
H5
5
4
P47
PFC protection
HC
6
14
P46
Loading EEPROM malfunction
EE
15
11
P45
High PN voltage protection
PH
11
13
P44
Low PN voltage protection
PL
21
12
P44
4-way valve reversal abnormal
U7
20
P48
Compressor Min frequence in test state
P0
Compressor rated frequence in test state
P1
Compressor maximum frequence in test state
P2
Compressor intermediate frequence in test state
P3
Frequency limiting (power)
LU
24
13
Compressor is running(normal)
1
The temperature for turning on the unit is
reached(normal)
8
Frequency limiting (module temperature )
EU
6
6
11
Normal communication
continu
ously
Summary of Contents for EXH09HL1W
Page 2: ...2010 10 ADL 2 62 599 73 60 74 ...
Page 5: ...210 10 ADL 5 62 599 75 60 77 2 ESD Requirements ...
Page 6: ...210 10 ADL 6 62 599 75 60 77 ...
Page 13: ...210 10 ADL 13 62 599 75 60 77 EXH09HL1W outdoor EXH12HL1W outdoor ...
Page 28: ...210 10 ADL 28 62 599 75 60 77 BOTTOM VIEW ...
Page 37: ...210 10 ADL 37 62 599 75 60 77 H6 Malfunction Flowchart ...