40
20 grids models
4.
Unsheathe all wires from the cable;
5.
Run the wires toward the terminal block;
6.
Connect the wires to the terminal block as shown in the
following figure.
7.
After connection secure the cable screwing the cable
gland ring.
8.
Fix the external box under the oven doing the corre-
sponding screw (if applicable in your model);
Gas models
To connect the power cable to the appliance, proceed as
follows:
1. Remove the left side panel of the oven;
2. Loose the ring to let the power cable run through the cable
clamp (see the figure)
3. Run the cable toward the terminal block;
4. Unsheathe all wires from the cable;
5. Connect the wires to the terminal block as shown in the
following figure.
6. After connection secure the cable screwing the cable
gland ring.
CAUTION
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid a hazard.
IMPORTANT
The manufacturer declines any liability if the current
national and local regulations and possible safety
regulations are not respected.
F.9
Safety device
The appliance is equipped with the following safety devices:
• Fuse - located behind the control panel.
For electrical models
• Cavity manual-reset safety thermostat - located behind the
control panel;
It switches off the electrical supply to the cavity heaters.
• Steam generator manual-reset safety thermostat - located
behind the control panel;
It switches off the electrical supply to the generator heaters.
• Automatic-reset thermal device inside the fan.
It activates if the fan overheats, protecting unit operation
and cuts off the electrical power to the appliance.
For gas models
• Cavity manual-reset safety thermostat - located behind the
control panel;
It shuts off the gas supply to the convector burner.
• Steam generator manual-reset safety thermostat - located
behind the control panel;
It shuts off the gas supply to the generator burner.
• Automatic-reset thermal device inside the fan.
It activates if the fan overheats, protecting unit operation
and cuts off the electrical power to the appliance.
NOTE!
Resetting operations must be carried out by speci-
alised technical personnel after eliminating the
causes of interruption.
F.10
Gas connection (for gas models)
F.10.1
General precautions
CAUTION
Make sure the appliance is suitable for the
type of gas available. Refer to the
dataplate.
Observe all local gas company regula-
tions! Connecting incorrectly may result in
burns.
• Gas ovens are not suitable for marine environment.
Summary of Contents for 10 GN 1/1
Page 3: ...3 Installation diagram 061 GN Gas model with boiler Touch and Digital code 597402000 ...
Page 4: ...4 Installation diagram 061 GN Gas model boilerless Touch and Digital code 597401Z00 ...
Page 6: ...6 Installation diagram 062 GN Gas model with boiler Touch and Digital code 597402600 ...
Page 7: ...7 Installation diagram 062 GN Gas model Boilerless Touch and Digital code 597402500 ...
Page 9: ...9 Installation diagram 101 GN Gas model with boiler Touch and Digital code 597402300 ...
Page 10: ...10 Installation diagram 101 GN Gas model Boilerless Touch and Digital code 597402200 ...
Page 12: ...12 Installation diagram 102 GN Gas model with boiler Touch and Digital code 597402900 ...
Page 13: ...13 Installation diagram 102 GN Gas model boilerless Touch and Digital code 597402800 ...
Page 14: ...14 Installation diagram 201 GN Electrical Model Boilerless Touch and Digital code 597402P00 ...
Page 15: ...15 Installation diagram 201 GN Gas Model with boiler Touch and Digital code 597402Q00 ...
Page 16: ...16 Installation diagram 201 GN Gas Model Boilerless Touch and Digital code 597402R00 ...
Page 18: ...18 Installation diagram 202 GN Gas Model with boiler Touch and Digital code 597402W00 ...
Page 19: ...19 Installation diagram 202 GN Gas Model boilerless Touch and Digital code 597402X00 ...
Page 45: ......
Page 46: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electrolux professional com ...