For UK:
The appliance must discharge via a backflow protection
device which gives fluid category 5 protection.
For Australia:
The appliance shall be drained to a certified waste trap
positioned at the drainage system connection point.
6 – 10 grids models
• The drain pipe can be run to the side or the back, if the oven
is not placed against a wall.
Special drain pipes kits are available on demand (code
922636 – 922637).
–
lateral drain:
–
back side:
20 grids models
Make sure that:
• the drain pipe is not more than 1 metre long, with inside
diameter not less than that of the oven discharge pipe (2").
• the drain pipe is able to withstand temperatures of at least
100
℃
.
• there are no constrictions in hoses or elbows in metal pipes,
along the entire drain path.
• horizontal sections where water can collect and stagnate
(minimum slope 5%) are avoided.
F.8
Electrical connection
IMPORTANT
The connection to the electrical power supply must
be in compliance with the current national and local
regulations.
Before connecting, make sure the voltage and frequency
match that given on the dataplate.
• Connect the appliance to the power supply in a permanent
way with an H07 RN-F type cable.
• Install the power cable in a metal or rigid plastic pipe without
any sharp parts.
• Install ahead of the appliance an omnipolar switch of
suitable capacity with contact opening distance of at least
3 mm.
Install the switch in the building's electrical system, in the
immediate vicinity of the appliance.
• Appliance max. leakage current is 5 mA.
• Install ahead of the appliance a device (interlocked plug,
lockable switch or similar devices) lockable in the open
position during maintenance.
• Connect the appliance to an efficient earthing system.
For that purpose, the connection terminal block has a
terminal with the symbol
for connecting the earth wire.
• Include also the appliance into an equipotential system. The
equipotential wire must have a section of at least 10 mm
2
.
This connection is made with the setscrew marked
,
located externally near the power cable entry.
F.8.1
Power cable installation
Electric models
To connect the power cable to the appliance, proceed as
follows:
1. Remove the left side panel of the oven;
2. If applicable in your model undo the screw fixing the
external box under the oven;
3.
Loose the ring to let the power cable run through the
cable clamp;
6 - 10 grids models
Cable clamp type for 220-240 V 3~
Cable clamp type for 380-415 V 3N~
D
Summary of Contents for 10 GN 1/1
Page 3: ...3 Installation diagram 061 GN Gas model with boiler Touch and Digital code 597402000 ...
Page 4: ...4 Installation diagram 061 GN Gas model boilerless Touch and Digital code 597401Z00 ...
Page 6: ...6 Installation diagram 062 GN Gas model with boiler Touch and Digital code 597402600 ...
Page 7: ...7 Installation diagram 062 GN Gas model Boilerless Touch and Digital code 597402500 ...
Page 9: ...9 Installation diagram 101 GN Gas model with boiler Touch and Digital code 597402300 ...
Page 10: ...10 Installation diagram 101 GN Gas model Boilerless Touch and Digital code 597402200 ...
Page 12: ...12 Installation diagram 102 GN Gas model with boiler Touch and Digital code 597402900 ...
Page 13: ...13 Installation diagram 102 GN Gas model boilerless Touch and Digital code 597402800 ...
Page 14: ...14 Installation diagram 201 GN Electrical Model Boilerless Touch and Digital code 597402P00 ...
Page 15: ...15 Installation diagram 201 GN Gas Model with boiler Touch and Digital code 597402Q00 ...
Page 16: ...16 Installation diagram 201 GN Gas Model Boilerless Touch and Digital code 597402R00 ...
Page 18: ...18 Installation diagram 202 GN Gas Model with boiler Touch and Digital code 597402W00 ...
Page 19: ...19 Installation diagram 202 GN Gas Model boilerless Touch and Digital code 597402X00 ...
Page 45: ......
Page 46: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electrolux professional com ...