30
E
TECHNICAL DATA
E.1
ELECTRICAL models data
No. of grids
MODELS
6 GN 1/1
6 GN 2/1
10 GN 1/1
10 GN 2/1
20 GN 2/1
20 GN 2/1
Power supply voltage
V
380–
415
220–
240
380–
415
220–
240
380–
415
220–
240
380–
415
220–
240
380–
415
220–
240
380–
415
220–
240
Phases
No.
3N~
3~
3N~
3~
3N~
3~
3N~
3~
3N~
3~
3N~
3~
Maximum rated current
A
16,4
28,4
31,9
55,2
28,3
48,9
55,9
96,6
56,3
97,3
97,8
169,1
Frequency
Hz
50–60
50–60
50–60
50–60
50–60
50–60
Electrical power
absorbed
kW
10.1 – 11.8
19 – 22.9
17.2 – 20.3
33.8 – 40.1
34.1 – 40.4
59.2 – 70.2
Fan motor power rating
kW
0.56
0.94
0.56
0.94
1.1
1.9
Steam unit power rating
kW
9
18
18
36
36
54
Convection unit power
rating
kW
10
20
18
34
36
63
E.2
ELECTRICAL and GAS models data
No. of grids
MODELS
6 Grids 1/1
6 Grids 2/1
10 Grids 1/1
10 Grids 2/1
20 Grids 1/1
20 Grids 2/1
Maximum oven load
Kg
30
60
50
100
100
200
Maximum pan/tray load
Kg
15
30
15
30
15
30
Weight ELECTRIC models
1
Kg
125,5
148,5
149,5
187
154
187
Weight GAS Models
Kg
140,5
163,5
157,5
201
162
201
Water pressure
kPa
100 – 450
100 – 450
100 – 450
100 – 450
100 – 450
100 – 450
1.
Models with boiler and triple glass door
E.3
GAS models data
No. of grids
MODELS
6 GN 1/1
6 GN 2/1
10 GN 1/1
10 GN 2/1
20 GN 1/1
20 GN 2/1
Power supply
voltage
V
220–
240
220–
230
220–
240
220–
230
220–
240
220–
230
220–
240
220–
230
220–
240
220–
230
220–
240
220–
230
Frequency
Hz
50
60
50
60
50
60
50
60
50
60
50
60
Electrical power
absorbed
kW
1.1
1.5
1.1
1.5
1.8
2.5
Maximum rated
current
A
4.8
6.5
4.8
6.5
7.8
11.3
Nominal heat
output
1
kW
19
32
31
47
54
100
Boiler unit nominal
heat output
kW
13
16
21
25
25
60
Convector unit
nominal heat
output
kW
12
24
21
35
42
70
Connection ISO 7/
1
Ø
1/2 ″ M
1/2 ″ M
1/2 ″ M
1/2 ″ M
1 ″ M
1 ″ M
Type of construction
A3
A3
A3
A3
A3
A3
1.
Values referred at 15
℃
, 1013 mbar.
Net heating value
G30: 45.65 MJoule/kg
G31 (LPG): 46.34 MJoule/kg
G20: 34.02 MJoule/m
3
G25: 29.25 MJoule/m
3
Gas models data for Australia
No. of grids
Models
6 GN 1/1
6 GN 2/1
10 GN 1/1
10 GN 2/1
20 GN 1/1
20 GN 2/1
Gas Types
U-
nit
Natu-
ral
Pro-
pane
Natu-
ral
Pro-
pane
Natu-
ral
Pro-
pane
Natu-
ral
Pro-
pane
Natu-
ral
Pro-
pane
Natu-
ral
Pro-
pane
Nominal gas
consumption
M-
J/h
76.0
74.5
128.2
125.3
123.3
121.7
187.9
184.3
216.0
211.0
400.0
392.0
Summary of Contents for 10 GN 1/1
Page 3: ...3 Installation diagram 061 GN Gas model with boiler Touch and Digital code 597402000 ...
Page 4: ...4 Installation diagram 061 GN Gas model boilerless Touch and Digital code 597401Z00 ...
Page 6: ...6 Installation diagram 062 GN Gas model with boiler Touch and Digital code 597402600 ...
Page 7: ...7 Installation diagram 062 GN Gas model Boilerless Touch and Digital code 597402500 ...
Page 9: ...9 Installation diagram 101 GN Gas model with boiler Touch and Digital code 597402300 ...
Page 10: ...10 Installation diagram 101 GN Gas model Boilerless Touch and Digital code 597402200 ...
Page 12: ...12 Installation diagram 102 GN Gas model with boiler Touch and Digital code 597402900 ...
Page 13: ...13 Installation diagram 102 GN Gas model boilerless Touch and Digital code 597402800 ...
Page 14: ...14 Installation diagram 201 GN Electrical Model Boilerless Touch and Digital code 597402P00 ...
Page 15: ...15 Installation diagram 201 GN Gas Model with boiler Touch and Digital code 597402Q00 ...
Page 16: ...16 Installation diagram 201 GN Gas Model Boilerless Touch and Digital code 597402R00 ...
Page 18: ...18 Installation diagram 202 GN Gas Model with boiler Touch and Digital code 597402W00 ...
Page 19: ...19 Installation diagram 202 GN Gas Model boilerless Touch and Digital code 597402X00 ...
Page 45: ......
Page 46: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electrolux professional com ...