Electro Industries/GaugeTech
Doc # E151701
5-20
5.4: INP2 Internal Modem with Dial-IIn In/Dial-O
Out Option
5.4.1: Hardware Overview
Q
The INP2 Option for the Nexus® 1262/1272 meter provides a direct connection to a standard
telephone line. No additional hardware is required to establish a communication connection between
the meter and a remote computer.
Q
The modem operates at up to 56k baud. The internal connection between the modem and the meter
includes a memory buffer. This enables the modem to connect to the phone line at any speed and to
change speed during the communication connection to the remote PC. The buffer between the meter
and the modem allows the meter to communicate into the modem at a constant speed while the
modem telephone line speed can vary. This eliminates the synchronizing problems that are common
with other devices. It also increases the effective throughput of the communication channel. This, in
turn, decreases connection time and connection costs.
Q
The modem supports both incoming calls (from a remote computer) and automatic dial-out calls
when a defined event must be automatically reported.
5.4.2: Hardware Connection
Q
When the INP2 Option is ordered, there are two RJ-11 jacks that pigtail from the back of the
meter (1. Line connection for the outside line 2. Phone connection for your phone). A standard
telephone RJ-11 plug can connect the meter to a standard PSTN (Public Switched Telephone
Network). The phone jack is the override of the modem function when the phone is in use.
With the device configured with the INP2 Option, the meter has dial-in capability and provides
remote access to other Modbus-based serial devices via the meter’s RS485 Gateway over your
phone line. The meter will recognize and respond to a Modbus Address of 1. With any other
address, the command will pass through the gateway and become a virtual connection between the
Remote Modbus Master and any Modbus Slave connected to the RS485 Gateway.
5.4.3: Dial-IIn Function
Q
The modem continuously monitors the telephone line to detect an incoming call. When an incoming
call is detected, the modem will wait a user-set number of rings and answer the call.
Q
The modem can be programmed to check for a password on an incoming call. If the correct
password is not provided the modem will hang up on the incoming call. If several unsuccessful
incoming call attempts are received in a set time period, the modem will lock out future incoming
calls for a user-set number of hours.
Q
When an incoming call is successfully connected, the control of communications is passed to the
calling software program. The modem will respond to computer commands to download data or
other actions authorized by the meter passwords.
Q
Refer to the
Communicator EXT User Manual
for instructions on programming the modem.
Summary of Contents for Nexus 1262
Page 1: ... The Leader in Power Monitoring and Control The Leader in Power Monitoring and Control ...
Page 2: ......
Page 4: ...Electro Industries GaugeTech Doc E151701 ...
Page 8: ...e Electro Industries GaugeTech Doc E151701 iv ...
Page 52: ...e Electro Industries GaugeTech Doc E151701 4 8 ...
Page 130: ...Electro Industries GaugeTech Doc E151701 10 14 ...
Page 133: ...Electro Industries GaugeTech Doc E151701 11 3 Fig 11 1 Form 9S Wye no PTs 3 CTs ...
Page 134: ...Fig 11 2 Form 9S Wye 3 PTs 3 CTs Electro Industries GaugeTech Doc E151701 11 4 ...
Page 135: ...Electro Industries GaugeTech Doc E151701 11 5 Fig 11 3 Form 9S 4 Wire Delta no PTs 3 CTs ...
Page 136: ...Fig 11 4 Form 9S 4 Wire Delta 3 PTs 3 CTs Electro Industries GaugeTech Doc E151701 11 6 ...
Page 139: ...Fig 11 7 Form 9S 3 Wire Delta no PTs 2 CTs Electro Industries GaugeTech Doc E151701 11 9 ...
Page 140: ...Fig 11 8 Form 9S 3 Wire Delta 2 PTs 2 CTs Electro Industries GaugeTech Doc E151701 11 10 ...
Page 141: ...Fig 11 9 Form 36S 2 5 Element Wye no PTs 3 CTs Electro Industries GaugeTech Doc E151701 11 11 ...
Page 142: ...Fig 11 10 Form 36S 2 5 Element Wye 2 PTs 3 CTs Electro Industries GaugeTech Doc E151701 11 12 ...
Page 143: ...Fig 11 11 Form 45S Wye no PTs 3 CTs Electro Industries GaugeTech Doc E151701 11 13 ...
Page 144: ...Fig 11 12 Form 45S Wye 2 PTs 3 CTs Electro Industries GaugeTech Doc E151701 11 14 ...
Page 145: ...Fig 11 13 Form 45S 3 Wire Delta no PTs 2 CTs Electro Industries GaugeTech Doc E151701 11 15 ...
Page 146: ...Fig 11 14 Form 45S 3 Wire Delta 2 PTs 2 CTs Electro Industries GaugeTech Doc E151701 11 16 ...
Page 150: ...Electro Industries GaugeTech Doc E151701 11 20 ...
Page 154: ...Electro Industries GaugeTech Doc E151701 12 4 Fig 12 5 Switchboard Meter Side View ...
Page 168: ...Electro Industries GaugeTech Doc E151701 12 18 ...
Page 176: ...Electro Industries GaugeTech Doc E151701 13 8 ...
Page 186: ...Electro Industries GaugeTech Doc E151701 A 2 ...
Page 187: ...Electro Industries GaugeTech Doc E151701 A 3 ...
Page 188: ...Electro Industries GaugeTech Doc E151701 A 4 ...
Page 189: ...Electro Industries GaugeTech Doc E151701 A 5 ...
Page 190: ...Electro Industries GaugeTech Doc E151701 A 6 ...
Page 206: ...Electro Industries GaugeTech Doc E151701 C 14 ...