Doc
#
E145701
2-12
2: Meter Overview and Specifications
Electro
Industries/GaugeTech
™
Powered by Innovation™
Environmental Rating
Storage:
(-20 to +70)
o
C
Operating:
(-20 to +70)
o
C
Humidity:
To 95% RH non-condensing
Faceplate Rating:
NEMA 12; mounting gasket
included
Measurement Methods
Voltage, Current:
True RMS
Power:
Sampling at 400+ samples per
cycle on all channels measured
readings simultaneously
A/D Conversion:
6 simultaneous 24 bit analog to
digital converters
Update Rate
Watts, VAR and VA:
Every 6 cycles
All other parameters:
Every 60 cycles (The Shark® 50
meter’s update rate is every 60
cycles for all parameters)
Communication Format
1. Shark® 100 meter: RS485 (485P) or RJ45 (INP10) port through backplate*
Shark® 100B meter: RJ45 (INP10) port through backplate is standard*
Shark® 50 meter: RS485 (485P) port through backplate is optional*
Shark® 50B meter: RS485 port and RJ45 port through backplate are standard**
*KYZ pulse comes with both the RS485P and INP10 communication ports.
**The Shark® 50B meter does not have KYZ pulse.
2. IrDA Port through faceplate (Shark® 50/50B meter does not have the IrDA port)